User's Manual

PROGRAMMING FOR FULL FEATURES --- (Supplementary Information)
In the Split-decoded operation mode, the keypad becomes a data entry tool of the system and its Data I/O port always
gives full feature data to the decoder. A keypad of simplified version also gives full features in Split-decoded mode. You
may try to program the required features even from a simplest keypad to make a full feature system. The programming
information supplied here is for the convenience of the owner who does not own a full feature keypad.
A Split-decoded system with only one keypad is a Master keypad. Just simply program all the features into it.
In a Split-decoded system with Master and Slave keypads, the major features MUST be programmed into the Master
keypad. The controller will only take these features to operate the system.
The other features can be programmed into each keypad independently. Each individual keypad, no matter a Master or
Slave is required to program with its User PINs, Codes and Cards to operate.
Each Programming Location in this manual is highlighted with MASTER or INDIVIDUAL for the owner’s programming
convenience.
------- The features MUST be programmed into the Master Keypad.
--- The features required to be programmed into each keypad individually including the PINs, Codes and
Cards. Those features are used in that keypad only and they can be repeated use in the other
keypad(s) in the system.
REMARK:
The feature of reading EM Cards only available on the keypads with EM Card reader.
No keypad is supplied with the Access Controller. User has to purchase the keypad seperately.
Only the keypads with DATA I/O port are compatible with the Access Controller.
SET SYSTEM INTO PROGRAMMING MODE WITH THE MASTER CODE
IMPORTANT NOTE:
1) DO NOT TURN OFF POWER while the keypad is in Programming Mode. Otherwise, it may cause data lost/error to the
programmed features in the memory.
2) The keypad beeps after power up. Wait 1 minute until the end of the power up delay, then key in the Master Code for
setting the system into programming mode.
3) For the owner’s convenience in programming at the first time, the factory has put a Master Code 0 0 0 0 into the
keypad (It is NOT a default code). To compromise security, in all cases, the owner should program a new Personal
Master Code to invalidate the factory set Master Code after the keypad is owned.
4) The Button has two functions in the keypads with Door Bell button. It is a door bell button while the keypad is in
normal operation; and it is equivalent to a
*
Button in programming mode.
MASTER CODE
The Master Code can be a factory set master code or the private master code that
was set by the owner.
Validate the master code with
* *
(or ) .
2-beep confirms a valid master code. The Mains LED (Amber) is constantly ON after the system is set in the
programming mode.
0000 **
MASTER CODE VALIDATION
.
. .
21
MASTER
INDIVIDUAL
INDIVIDUAL
DIRECT ACCESS TO PROGRAMMING MODE WITH THE “DAP” CODE – 8 0 8 0
Set System Into Programming Mode With DAP Code In Case Of The Master Code Is Forgotten ! !
The owner requires to apply the following procedures precisely to set the system into programming mode
with the DAP code 8 0 8 0.
1) Switch OFF all the power for 1 minute to ensure that the system is fully discharged.
2) Swich ON power again. The system is in Power-up Mode for 1 minute and the buzzer gives beeps during the whole
period. This is the only time limit for setting the system to Direct Access to Programming (DAP).
3) Press the Egress Button (EG IN) once first to enable the DAP function.
4) Key in the DAP Code 8 0 8 0 and validate it with
* *
(or ), the existing Master Code in the memory is
erased and the power up beep stops. The keypad turns itself into programming mode like using the Master Code and
it is ready to accept the new programming data.
5) If the Egress Button is not pressed and the DAP code is not keyed in within the power up period, the system will set
itself to normal operation mode. To set it back to power-up mode, repeat procedures 1-4.
DAP CODE
The DAP code is fixed on 8 0 8 0 and it is valid only in the Power-up Period after the Egress Button is pressed.
Validate the DAP code with the
* *
(or )
.
2-beep confirms the system is in the Programming Mode; and the Mains LED is constantly ON.
See “RECORD A MASTER CODE” at “Location 01” for the details of programming a new master code.
NOTES FOR SPLIT-DECODED OPERATION:
1. It is necessary to press the Egress Button on the keypad unit once to enable the DAP function.
2. In Split-decoded mode, the Egress Button is connected to the controller unit but not to the keypad. The owner has
to use a short wire to make a momentary touch of the "EG IN" terminal of the keypad to "GND (
-
)" to simulate of
pressing the Egress Button in order to enable the DAP function.
3. This procedure is required for both Master keypad and Slave keypad in Split-decoded operation with DAP Code going
into programming mode.
8080
**
DAP CODE VALIDATION
.
.
.
.
EGRESS BUTTON
PRESS ONCE
22
INDIVIDUAL