THE SPLIT-DECODED CONTROLLER UNIT (Figure 1)
THE MAIN CIRCUIT BOARD OF THE CONTROLLER --- (Figure 2)
NOTE:
Factory suggest that the work of timer adjustment and change of jumper settings on the main circuit board are
to be done by the Installer only.
No adjustment/setting change is required for Split-decoded operation with the ex-factory settings.
6
LINK-UP JUMPER
OFF-->ON-->OFF
CODE LEARNING
BUTTON
(DA-2800 ONLY)
REMOTE CONTROL
SIGNAL & STATUS
(DA-2800 ONLY)
INTERNAL SIREN
& DOOR CHIME
CONNECTION
TERMINALS
MAINS
OUTPUT BEEP JUMPER
ON OR OFF
FUNCTION MODE JUMPER
1. SPLIT-DECODED
2. STAND ALONE MODE 1
3. STAND ALONE MODE 2
ADJUSTABLE TIMER
FOR OUTPUT 1
TURN CLOCKWISE FOR
MAXIMUM TIME
RECEIVER FOR
REMOTE CONTROL
(DA-2800 ONLY)
EGRESS DELAY , WARNING AND ALARM (Location 90)
CONFIGURATIONS OF THE EGRESS WARNING AND ALARM
Key in the number to enable 1 of the 6 configurations described below:
1
--- Momentary Contact Mode without Warning -- (Default)
Press the Button once. No warning or alarm is given during Egress Delay.
Good for silent area. The people have to wait for the door open until the delay time
reaches.
2
--- Momentary Contact Mode with Warning Beep
Press the Button once. The system gives Warning Beeps during the Egress Delay.
Good for the place required attention. The keypad beeps during the people are waiting for
the door open.
3
--- Momentary Contact Mode with Warning Beep & Alarm
Press the Button once. The system gives Warning Beeps and also activates its Alarm O/P
during the Egress Delay
Good for door for the authorized people only. The keypad beeps and report alarm to a
security system during the people are waiting for the door open.
This is usually an “Emergency Exit”. The door can be opened with the Keypad without
triggering of the Buzzer and Alarm Output.
4
--- Holding Contact Mode without Warning
Press and hold the Button. No warning or alarm is given during the Egress Delay.
Good for the silent area. The people require to press & hold the button until the delay time
reaches for the door open.
5
--- Holding Contact Mode with Warning Beep
Press and hold the Button. The system gives Warning Beeps during Egress Delay.
Good for the place required attention. The keypad beeps while the button is kept pressed
during the people are waiting for the door open.
6
--- Holding Contact Mode with Warning Beep & Alarm
Press and hold the Button. The system gives Warning Beeps and also activates its Alarm
O/P during Egress Delay.
This is usually an “Emergency Exit”. The door can be opened with the Keypad without
triggering of the Warning and Alarm.
EGRESS DELAY TIMER
0
--- No Delay – (Default)
Output 1 activates instantly (the door is released instantly) when the Egress Button is pressed.
1
99
--- Egress Delay Timing
Put any number of 1 to 99 into the box to enable the Egress Delay. The number is the time in second, which starts to
count when the Egress Button is pressed. Output 1 activates (the door is released) when the delay time reaches.
NOTE:
1) Momentary Contact -- The Egress Delay starts to count when the egress button is momentarily pressed. Output 1
activates automatically (door is released) when the delay time reaches.
2) Holding Contact -- The user MUST hold the egress button in contact for the whole period of the Egress Delay time
until Output 1 activates. If the egress button is released before the end of the Egress Delay, the timer will stop to count
and reset.
3) The Egress Delay does not affect the operation of the User PINs/Cards for Output 1. The User PINs/Cards always
give INSTANT action.
Examples: (please see the following page)
FUNCTION MODES VALIDATIONDELAY TIMELOCATION
1
-
6 0
or
1
-
99 #90
37