User's Manual

9
Example – Change of the Link-up Code ( The Master Code of the Master Keypad)
a) Put the Link-up Jumper of the Decoder from OFF to ON
OFF ON
b) Set the Master Keypad to Programming Mode
EXISTING MASTER CODE
*
*
c) Set a New Master Code to the Master Keypad
NEW MASTER CODE #
d) Set the Master Keypad to exit from Programming Mode
*
*
e) The Link-up in the system is done automatically
BEEP BEEP ----- From Keypad
f) Put the Jumper back to OFF
ON OFF
g) The system is in Split-decoded operation with the new Link-up Code
THE FUNCTION MODE JUMPER -- (AVAILABLE ON DA-2800 ONLY)
Three positions are available for the Function Mode Jumper. Position 1 is for Split-decoded Mode and the positions 2 &
3 are for Stand Alone Modes.
POSITION 1 – SPLIT-DECODER (MAINS LED LAMP FLASHING)
Position 1 is for Split-decoder mode. All the functions and the 3 output relay operation manners follow the programmed
settings in the Master keypad. All the functions of the decoder are programmable from the keypad unit. The DA-2800
system is controlled by the keypads and the remote control keys in the Split-decoded mode.
POSITION 2 – STAND ALONE MODE 1 – START / STOP FOR OUTPUT 1 (MAINS LED LAMP ON)
Position 2 is one of the settings for Stand Alone mode. All the three Output Relays are controlled by the RF Remote Key
with the following functions:
Output 1 – Start / StopControlled by Channel 1 of the RF remote key. Press the Button A once to start and press the
button once again to stop.
Output 2 – Start / StopControlled by Channel 2 of the RF remote key. Press the Button B once to start and press the
button once again to stop.
Output 3 Manual Momentary Controlled by Channel 3 of the RF remote key. The output relay operates (Starts) as
long as the Button C is pressed and it stops when the button is released.
POSITION 3 – STAND ALONE MODE 2 – ADJUSTABLE TIMER FOR OUTPUT 1 (MAINS LED LAMP ON)
Position 3 is one of the settings for Stand Alone mode. All the three Output Relays are controlled by the RF Remote Key
with the following functions:
Output 1 – Adjustable Timer – Controlled by Channel 1 of the RF remote key. Press the Button A once to start the timer
and it resets automatically after time out. It is adjustable 1-30 seconds. It is convenient for
setting the time for door strike. Turn the timer clockwise for maximum time. See Figure 2.
Output 2 – Start / StopControlled by Channel 2 of the RF remote key. Press the Button B once to start and press the
button once again to stop.
Output 3 Manual Momentary Controlled by Channel 3 of the RF remote key. The output relay operates (Starts) as
long as the Button C on the remote key is pressed and it stops when the button is released.
ENTRY MODES VALIDATIONLOCATION
1
or
270 #
USER PIN ENTRY MODE Auto or Manual (Location 70)
USER PIN ENTRY MODES
Two modes 1 and 2 are available for User PIN entry options. The EM Card is always in Auto Entry Mode and is not
affected by the selection here.
1
--- Auto Entry Mode
Auto Entry Mode requires no pressing of the
#
key following the User PIN for code checking.
In the Auto Entry Mode, the User PINs MUST be set in the same digit length of the Master Code (For example, if
the Master Code is 5 digits, then all User PINs must be in 5 digits as well. All other User PINs not in 5 digits become
invalid). When the number of digits reaches, the system will check the User PIN automatically. Good for high traffic
access control.
2
--- Manual Entry Mode – (Default)
Manual Entry Mode always requires the
#
key following of the User PIN for code checking. The User PINs can be 4-8
digits arbitrary and they are NOT required to be in the same digit length of the Master Code. Manual Entry increases
the level of security in the code trial by the unauthorized people.
PACIFIER TONES ON-OFF SELECTION (Location 71)
PACIFIER TONES ON-OFF MODES
The Pacifier Tone is the Beep Tones from the keypad, which include the tones of Successful Key entry (1 beep), the
Output Operation Announcer (2 beeps or 1 long beep) and the Unsuccessful User Code/Card entry (5 beeps).
NOTE :
The beeps for the Warning and the Power-up Delay do not belong to pacifier tones and can not be set to OFF.
1
--- Pacifier Tone ON – (Default)
All the Pacifier Tones available from the keypad are enabled. They are the response tones indicating the operation
status of the keypad after the Card/User Code is entered.
0
--- Pacifier Tone OFF
All the Pacifier Tones are OFF. Good for place needs for a silent environment.
OUTPUT OPERATION ANNOUNCER (Location 72)
OUTPUT OPERATION ANNOUNCER
The announcer gives notification beep to the users and the visitors on the operation status of the outputs. There are
two notification modes available for the selection.The notification is also OFF while the Pacifier Tone OFF mode in the
Location 71 is selected.
1
--- 1 Second Long Notification -- (Default)
1 second notification beep is given when the output relay is activated with a valid Card/Code or Egress Button. It is
prepared to notify the person outside the door when the lock is released and the door can be opened. It is good for
the door lock device gives no sound when it activates, such as a magnetic lock.
0
--- 2 Short Beeps Notification
2 short beeps notification is given when the output is activated with a valid Card/Code.
FUNCTION MODES VALIDATIONLOCATION
FUNCTION MODES VALIDATIONLOCATION
1
or
0
1
or
0
#
#
71
72
34
INDIVIDUAL
INDIVIDUAL
INDIVIDUAL