User's Manual

36
Auto Entry Mode requires no pressing of the # key after code entry for code checking.
In the Auto Entry Mode, the User Codes MUST be set in the same digit length of the
Master Code (For example, if the Master Code is 5 digits, then all User Codes must be in 5
digits as well. All other User Codes not in 5 digits become invalid). When the number of digits
reaches, the system will check the User Code automatically. Good for high traffic access control.
USER CODE ENTRY MODE – Auto or Manual (Location 70)
(1) LOCATION
Key in Location
(2) USER CODE ENTRY MODES
Two modes 1 and 2 are available for User Code entry options. The EM Card is always in Auto
Entry Mode and is not affected by the selection here.
--- Auto Entry Mode
--- Manual Entry Mode – (Default)
(3) VALIDATION
Press
key once. Two-beep confirms the entry
PACIFIER TONES ON-OFF SELECTION (Location 71)
(1) LOCATION
Key in Location
(2) FUNCTION MODES FOR PACIFIER TONES
Pacifier Tone is the Beep Tones from the keypad, which include the tones of Successful Key entry
(1 beep) and the Unsuccessful User Code/Card entry (5 beeps).
NOTE:
The beeps for the Warning and the Power-up Delay do not belong to pacifier tones and can not be
OFF.
--- Pacifier Tone ON – (Default)
--- Pacifier Tone OFF
(3) VALIDATION
Press key once. Two-beep confirms the entry
All the Pacifier Tones available from the keypad are enabled. They are the response tones
indicating the operation status of the keypad after a Card/User Code is entered.
All the Pacifier Tones are OFF. Good for place needs for a silent environment.
VALIDATIONLOCATION
or

ENTRY MODES
(2) (3)(1)

FUNCTION MODES VALIDATIONLOCATION
or

(2) (3)(1)

Manual Entry Mode always requires the # key following the User Code for code checking.
The User Codes can be 4-8 digits arbitrary and they are NOT required to be in the same
digit length of the Master Code. Manual Entry increases the level of security in code trial by
the unauthorized people.