User's Manual

41
EGRESS DELAY , WARNING AND ALARM (Location 90)
(1) LOCATION
Key in Location
(2) CONFIGURATIONS OF THE EGRESS WARNING AND ALARM
Key in the number to enable 1 of the 6 configurations described below:
--- Momentary Contact Mode without Warning -- (Default)
--- Momentary Contact Mode with Warning Beep
--- Momentary Contact Mode with Warning Beep & Alarm
--- Holding Contact Mode without Warning
--- Holding Contact Mode with Warning Beep
--- Holding Contact Mode with Warning Beep & Alarm
(3) EGRESS DELAY TIMER
--- No Delay – (Default)
Output 1 activates instantly (the door is released instantly) when the Egress Button is pressed.
 --- Egress Delay Timing
Put a number of 1 to 99 into the box to enable the Egress Delay. The number is the time in
second, which starts to count when the Egress Button is pressed. Output 1 activates (the door is
released) when the delay time reaches.
CONFIGURATIONS VALIDATIONDELAY TIMELOCATION
-

or
-
 
Press and hold the Button. The system gives Warning Beeps during Egress Delay.
Good for the place required attention. The keypad beeps while the button is kept pressed during
the people are waiting for the door open.
(2) (4)(3)(1)
Press and hold the Button. No warning or alarm is given during the Egress Delay.
Good for the silent area. The people require to press & hold the button until the delay time
reaches for the door open.
Press the Button once. The system gives Warning Beeps and also activates its Alarm O/P during
the Egress Delay
Good for door for the authorized people only. The keypad beeps and report alarm to a security
system during the people are waiting for the door open.
This is usually an “Emergency Exit”. The door can be opened with the Keypad without triggering
of the Buzzer and Alarm Output.
Press the Button once. The system gives Warning Beeps during the Egress Delay.
Good for the place required attention. The keypad beeps during the people are waiting for the
door open.
Press the Button once. No warning or alarm is given during Egress Delay.
Good for silent area. The people have to wait for the door open until the delay time reaches.
Press and hold the Button. The system gives Warning Beeps and also activates its Alarm O/P
during Egress Delay.
This is usually an “Emergency Exit”. The door can be opened with the Keypad without triggering
of the Warning and Alarm.
