User's Manual
47
PROGRAMMING MAKE SIMPLE – For General Users
The DK-2822 is a multi purpose keypad. It has many functions for user’s selection. For those general
users taking the keypad for door strike only, most of the features can be kept in their Default values.
Only the User
Code
s / Cards and a private Master Code are required to program.
The keypad accepts 1) Card only, 2)
Code
only, 3) Card +
Code
or 4) Card + Common User
Code to operate its outputs.
PROGRAMMING
NOTE:
a) The button is equivalent to the button in the keypad with bell button.
b) Wait 1 minute until the end of power up delay, or keyin to stop the power-up delay
instantly and set the keypad to normal operation.
1) Set System in Programming Mode with The Factory Set Master Code 0 0 0 0
---- 2 beeps, system is in Programming Mode
Note: If the Master Code is forgotten, use the DAP Code to set the system into programming mode.
See DAP CODE 2828 in page 15 for the details.
2) Change The Factory Set Master Code to Owner’s Private Master Code for Security Reason
----
3) Record an “EM Card” to Operate The Output 1 for Door Open
(a) (b) (c) (d) (e)
(a) 10 = Programming Location for Output 1
(b) 1 = Programming option for EM Card only
(c) 001 = One of the 1,000 User IDs for the User
Code
/Card from 000-999
(d) Read Card = Put the Card close to the card reader
(e) # = Confirm the card is read, 2 beeps
4) Set an “User Code” to Operate The Output 1 for Door Open
(a) (b) (c) (d) (e)
(a) 10 = Programming Location for Output 1
(b) 2 = Programming option for User
Code
only
(c) 002 = One of the 1,000 User IDs for the User
Code
/Card from 000-999
(d) 8321 = The User
Code
for door open. It is for example here only
(e) # = Confirm the User
Code
, 2 beeps
READ CARD
2 beeps, 3 2 8 9 is a Master Code for example here only.
It replaces the old master code 0000.