User's Manual
5) To pr
ogram a new Master Code to replace the old one. See “Record A Master Code”
stated at
“Location
01” for the details.
NOTE:
The keypad will set itself to normal operation mode 1 minute after power-up if the Egress Button is
not pressed and the DAP code is not keyed in. To set keypad back to power-up mode, repeat
procedures 1-4.
SYSTEM REFRESHING WITH “REFRESHING CODE” --- 9 9 9 9
The keypad can be r
efreshed by cleaning all the programmed old data and set it back to default
values except the Master Code.
REFRESHING CODE V
ALIDATION
NOTE:
a)
b)
c)
Mak
e sure that system refreshing is really required before entering the refreshing code.
Refreshing takes few minutes. The status LED (amber) keeps flashing during refreshing.
The keypad is back to its default value after refreshing. Re-program of the desired values are
necessary.
SYSTEM
CODES
FUNCTION CODE ENTRY RESULTS
0 0
0 0
system in programming Mode at the first
Factory Set Master Code for User to set
time.
THIS IS NOT A PERMANENT SYSTEM
CODE & IT IS CHANGED IF A NEW
MASTER CODE IS PROGRAMMED.
OR
NEW MASTER CODE
System in
Programming M
ode
9 9 9 9
REFRESH CODE -- Refresh the system
and set all its function back to default
values.
All programmed
dat
a are cleared
and back to the
default values
except the Master
Code
2 8 2 8
DAP CODE-- Direct access to
programming mode. Valid only in the
power-up delay period
System in
Programming M
ode
0 9 9 9
USER Codes / Cards whole group
clearing Code for the selected Location
LOCATIONS:
10--- User Group 1
20--- User Group 2
40--- Vistor Group
41--- Duress Group 1
42--- Duress Group 2
LOCATION NO.
Whole group
of users
in the
selected location
are cleared
* *
Exit
Programming Code
The system back
to
normal opration
after programming
Pacifier Tone
ON-OFF
7 1
FUNCTION MODE:
0---NO
Notification
2---2 Short Beeps
1---1 Second Long Beep
FUNCTION MODE:
0---OFF
1---ON
FUNCTION MODE:
0---OFF
1---ON
FUNCTION MODE
Mode
= 1,
ON
7 2
Output An
nounc
er
FUNCTION MODE
7 3
Standby LED Fl
ashing
FUNCTION MODE
Mode
= 1,
Flashing ON
Mode
= 1
1 Second
Long Beep
Pacifier Tone
8 0
Door For
ced Open
Warning & Time
FUNCTION MODE / TIME:
0---OFF
1-999
Seconds
FUNCTION / TIME
Mode = 0,
Door
Forced
Open
Warning OFF
8 1
Propped-up Warnin
g &
Time
FUNCTION / TIME
M
ode = 0,
Propped-up
W
arning OFF
9 0
Egress Delay Warni
ng
CODE 1
-
FUNCTION
MODE:
1---Momentary
, No warning
2---Momentary, with
warning
4---Hold Contact, No
warning
5---Hold Contact, with
warning
CODE 2
-
DELAY TIME:
0---No Del
ay
1-99 Seconds
CODE 1
CODE 2
Mode = 1
M
omentary,
No warning
TIME = 0
No Delay
9 4
Operation M
ode
FUNCTION MODE:
MODE
Mode = 0
Keypad
M
ode
1---Server M
ode
0---Keypad Mode
DIRECT ACCESS TO PROGRAMMING MODE WITH “D
AP” CODE -- 2 8 2 8
In case the Master Code is forgotten, apply the following procedures precisely to set keypad
into programming mode with DAP code:
1)
2)
3)
4)
S
witch OFF all the power for 1 minute to ensure that the keypad is fully discharged.
Switch ON power again. The keypad is in Power-up Mode for 1 minute. The buzzer gives
continuous beeps and the Status LED is flashing. This is the only time frame to accept the DAP
code.
Press the Egress Button (the button connecting accross EG IN, (Terminal 9) and (-)GND,
(Terminal 15) once to enable the keypad for accepting DAP code. The power-up beep stops after
the Egress Button is pressed.
Key in the DAP code and validate it with (or ). The Status LED is
ON and the keypad is in programming mode like using Master Code. It is ready to accept new
programming data as long as you like until exit programming mode.
PRESS ONCE
EGRESS BUT
TON DAP CODE VALIDATION