User's Manual

4 to
8 Digits

MASTER CODE (Location 01)
LOCATION MASTER CODE VA
LIDATION
(1) LOCATION
Key in Locat
ion
(2) MASTER CODE
(3) VALIDATION
Master Code is the authorization code for setting the system to programming mode. It is NOT
an User Code operating the output relays.
The Master Code can be 4 to 8 digits.
When a new master code is keyed in and confirmed, the old master code is replaced.
The master code is also the Link-up Code between the keypad and the optional decoder in
Split-decoded operation.

(2)(1) (3)
Press k
ey once. Two-beeps confirms the entry.
Example:
Set a
Master Code “2 2 3 3” ----

SUPER USER CODE (Location 02)
The
Super User Code has TWO functions. It is prepared to operate the three outputs and make
operation of inhibit enable / disable to those outputs.
(1) LOCATION
Key in Location
(2) SUPER USER CODE
The Super User Code can be 4 to 8 digits.
When a new Super User Code is keyed in and confirmed, the old one is replaced.
(3) VALIDATION
Pressing key to confirm code entry.
Example:
a) Set a
Super User Code “2 5 8 0” ----
b) Deleted a Super User Code from memory: Key in the Location number and #. ----
4
to
8 Digits

(1) (2) (3)
LOCATION SUPER USER CODE VALIDATION


 
READ CARD
(c) 003 = One
of the 1,000 User IDs for the User
Code
/Car
d from 000-999
(d) Read Card = Put the Card close to the card reader
(e) 6123 = The User
Code
to
be used wi
th the EM Card. It is for example here only.
(f ) # = Confirm the Card+Code is stored, 2 beeps
6) Record an “EM Card + Commom User Code” to Operate The Output 1 for Door Open
(a)
(b)
(c)
(d) (e)
(a) 10 = Programming Location for Output 1
(b) 4 = Programming option for EM Card + Common User Code
(c) 004 = One of the 1,000 User IDs for the User
Code
/Car
d from 000-999
(d) Read Card = Put the Card close to the card reader
(e) # = Confirm the card is read, 2 beeps, the Common User Code goes to this User ID
automatically
(f ) A Common User Code (for example: 1 3 5 7) MUST be set at the Programming Location 03
first. Common code can be used for all the EM Cards in this operation mode.
REMARK:
If more User
Code
s and
Cards are required for Output 1, repeat the procedures (3) , (4) , (5) or (6)
above with other User IDs, such as 005, 006, 007 --- 999 etc. Total 1,000 users are allowed. See
Programming Location 10 for the details.
7) Close The Programming Mode
---- 2 beeps
The programming mode is closed. The keypad is back to normal operation mode
OPERA
TION
1) Open The Door with EM Card
--- 2 beeps, the door is open
2) Open The Door with User Code
--- 2 beeps, the door is open
3) Open The Door with EM CARD + User Code
--- 2 beeps, the door is open
4) Open The Door with EM CARD + Common User Code
--- 2 beeps, the door is open
READ CARD
READ CARD
READ CARD
proprietary)
5) Record an “EM Card + User
Code
” to Operate The Output 1 for Door Open
(a) (b) (c) (d) (e) (f)
(a) 10 = Programming Location for Output 1
(b) 3 = Programming option for EM Card + User
Code
. (
The User
Code
can
be repeated use or
  
READ CARD