User's Manual
PROGRAMMING MAKE SIMPLE – For General Users
This i
s a multi purpose keypad. It has many functions for user’s selection. For those general users
taking the keypad for door strike only, most of the features can be kept in their Default values. Only
the User
Code
s /
Cards and a private Master Code are required to program.
The keypad accepts 1) Card only, 2)
Code
only,
3) Card +
Code
or 4) Card
+ Common User
Code to operate its outputs.
PROGRAMMING
NOTE:
a) The
button is equivalent to the button in the keypad with bell button.
b) Wait 1 minute until the end of power up delay, or keyin to stop the power-up delay
instantly and set the keypad to normal operation.
1) Set System in Programming Mode with The Factory Set Master Code 0 0 0 0
---- 2 beeps, system is in Programming Mode
Note: If the Master Code is forgotten, use the DAP Code to set the system into programming mode.
See DAP CODE 2828 in page 15 for the details.
2) Change The Factory Set Master Code to Owner’s Private Master Code for Security Reason
----
3) Record an “EM Card” to Operate The Output 1 for Door Open
(a) (b) (c) (d) (e)
(a) 10 = Programming Location for Output 1
(b) 1 = Programming option for EM Card only
(c) 001 = One of the 1,000 User IDs for the User
Code
/Car
d
from 000-999
(d) Read Card = Put the Card close to the card reader
(e) # = Confirm the card is read, 2 beeps
4) Set an “User Code” to Operate The Output 1 for Door Open
(a) (b) (c) (d) (e)
(a) 10 = Programming Location for Output 1
(b) 2 = Programming option for User
Code
onl
y
(c) 002 = One of the 1,000 User IDs for the User
Code
/Card
from 000-999
(d) 8321 = The User
Code
f
or door open. It is for example here only
(e) # = Confirm the User
Code
, 2
beeps
READ CARD
2 beeps,
3 2 8 9 is a Master Code for example here only.
It replaces the old master code 0000.
OPERATION AND FUNCTIONS OF THE SUPER USER CODE
1) Operate Output 1 and 2
The operation
of the Super User Code is just like a normal User Code. Simply key-in the Code with a
specific output number for the desired Output. The Super User Code can also be used to reset an
operating output timer instantly.
---------- Output 1 Activates or Resets
---------- Output 2 Activates or Resets
Optional Functions Controlled by Super User Code for Output 1
Apart from controlling of the two outputs 1 and 2; the Super User Code can also be used to enable
the optional functions controlling Output 1 for user convenience or security enhancement.
Super User Code and Egress Button are excluded from any system inhibition and lockup functions;
they are valid for door open at anytime for safety.
2) Override The Door Lock Controlled by Output 1 (Keep Door Un-locked)
The Output 1 is usually for door lock control. In some situations, the door may require un-locked for
a period of time to allow door opening without User Code or EM Card for entry / exit convenience.
This function Starts / Stops in toggle with the following code entry.
---------- The Door is Un-locked, Start / Stop in Toggle
NOTE :
•
•
•
•
3) Pause The Scheduled Daily Inhibition for Output 1 (T
emporarily Disable The Inhibition)
The scheduled inhibition can be programmed and applied to Output 1 with daily start and stop times.
It can be stopped temporarily if required; such as the staff work overtime after office hours going
into the inhibition period. This function Starts / Stops in toggle with the following code entry. It can
be done before or during the inhibition period.
---------- Door Lock Operation Resumes, Start / Stop in Toggle
NOTE :
•
The “INHIBIT” LED (R
ed) is ON in inhibition and turns to Flashing while pause is into effect.
•
See
Programming Locations 55 & 56 for more information Daily Inhibition.
SUPER USER
CODE
SUPER USER
CODE
SUPER USER
CODE
SUPER USER
CODE
The door is un-lock
ed while the function is enabled. The “Output 1” LED (Green) turns ON.
Do not forget to stop this function after use because the door is un-locked. Also, the system
refuses the optional functions (3) & (4) while Override function comes into effect.
This feature is good for all the “Fail-safe electric locks”.
“Fail-secure electric lock” requires power to keep in un-locked condition. It takes high current
all the time while the function comes into effect and may cause damage to it. This function is not
recommended for Fail-secure electric lock.