User's Manual
VISITOR CODES (FOR OUTPUT 1 ONL
Y) (Location 40)
The Visitor
Codes are temporary user codes for Output 1 (mainly for door strike in access control).
They can be programmed as “One Time Codes” or “Codes with Time Limit”. The Visitor Codes
will be cleared automatically after use if they are one time codes, or, when the allowed time
expires.
(1) LOCATION
Key in Location
(2) VISITOR ID
--- 50 Visitor IDs for the 50 visitor codes. They are T
wo-digit numbers
---
(3) VALID PERIOD
The codes in this box MUST be two digits and they represent the time of operation.
--- One Time Code
One Time Code has no time limit but it can only be used for ONCE. It is cleared after use.
- --- Time Limit in Hour(s)
The
Visitor Code can be set with the valid time limit of 1 Hour to 99 Hours with a two-digit
number of 01 to 99. The visitor code is cleared when the time limit reaches.
4-8 DIGITS
-
or
-
VISITOR CODE VALIDATIONLOCATION VISITOR ID VALID PERIOD
(5)(4)(3)(2)(1)
-
Clear all the Visitor Codes in Location 40. Please see the Programming
example below for the details.
(4) VISITOR CODES
NOTE: All V
isitor Codes will be cleared after power down to prevent extension/confusion of
their valid time limit.
(5) VALIDATION
Press key once. Two-beeps confirms the entry.
The Visitor Codes can be 4-8 digits for Manual Mode code entry.
The Visi
tor Codes MUST be in the same digit length with the Master Code for Auto Mode code entry.
The Visitor Codes can not r
eset Duress Output.
When a new Visitor Code is put in the same Code box, the old code is replaced.
OUTPUT OPERATION ANNOUNCER (Location 72)
(1) LOCA
TION
Key in Location
(2) FUNCTION MODES FOR OUTPUT ANNOUNCER
Output announcer gives notification beep on the operation status of the outputs. There are two
notification modes available for the selection.The notification is also OFF while the Pacifier Tone OFF
mode in the Location 71 is selected.
--- No Notification
The output operation notification is OFF but does note affect the normal pacifier tones.
--- 1 Second Long Notification -- (Default)
1 second notification beep is given when the output relay activates. It is prepared to notify the
person outside the door when the lock is released and the door can be opened. It is good for door
lock that gives no sound when it activates, such as a magnetic lock.
--- 2 Short Beeps Notification
2 short beeps notification is given when the output relay activates.
(3) VALIDATION
Press
key on
ce . Two-beeps confirms the entry
STA
TUS LED FLASHING ON-OFF DURING STANDBY (Location 73)
(1) LOCA
TION
Key in Location
(2) FUNCTION MODES FOR STANDBY FLASHING LIGHT
Some people find the flashing light of the status LED (the amber LED) is annoying during standby,
especially at the night time. The standby flashing can be ON-OFF with the setting here.
--- Standby Flashing ON -- (Default)
The Status LED gives Standby Flashing all the time. It also gives the light indications showing the
operation status of the system.
--- Standby Flashing OFF
The Stan
dby Flashing is OFF but it does not affect the system status indications.
(3) VALIDATION
Press
key on
ce . Two-beeps confirms the entry
FUNCTION MODES
VALIDATIONLOCATION
or
(2) (3)(1)
FUNCTION MODES
VALIDATIONLOCATION
or
(2) (3)(1)
NOTE:
In
multi-station operation, the output announcer only goes to the keypad that has been operated but
not all the keypads in the system.