User's Manual
OUTPUT MODE & TIMING FOR OUTPUT 1 and 2 (Locations 51 & 52)
The t
wo relay outputs are programmable for Start/Stop or Timing modes. Apart from door access
control, alarm arm-disarm control, they are also universal timers for automatic operators in
industry with their 99,999 seconds (over 24 hours) programmable timer.
(1) LOCATIONS
-- Location for Output 1
-- Location for Output 2
(2) OUTPUT MODE & TIMING
Start /Stop Mode (Toggle)
The
number 0 sets the output to Start / Stop mode. The output Starts when an User Code and/or
Card is entered/read; the output Stops when an User Code and/or Card is entered/read again.
-- Seconds Momentary --- (Default -- Momentary 5 Seconds)
The output can be set in Momentary Mode with the time of 1 second to 99,999 seconds. The
output will reset automatically when the time expires.
(3) VALIDATION
Press key once. Two-beeps confirms the entry.
RESET OUTPUT TIMER WITH SUPER USER CODE
The Output Timer can be RESET manually at anytime with the Super User Code that operates
the desired output before the end of the time.
Example:
Reset Output 1 Timer -- ------------- Output 1 stops
Reset Output 2 Timer -- ------------- Output 2 stops
SUPER USER CODE
SUPER USER CODE
OUTPUT MODE & TIME VALIDATIONLOCATIONS
-
or
-
(3)(2)(1)
SYSTEM REAL-TIME-CLOCK (Location 55)
This 24 hour
real-time-clock provides the daily time base for starting and stopping the function of
inhibition to relay output 1 (mainly for electric door lock strike).
No real-time-clock setting is required if daily start-stop inhibition at Location 56 is not
enabled.
(1) LOCATION
Key in Location
(2) CURRENT REAL TIME
– The current time in Hour and Minute. The allowed time figure is 00:00 – 23:59
The time setting is based on 24 hours daily with the first two digits for hours and the last two digits
for minutes. The time in second always starts at 0 0.
(3) VALIDATION
Press key once.
Two-beep confirms the setting and the clock starts to count in 24 hour basis from the programmed
current time.
Programming Examples:
a) Set the current time of “10:30” (AM) to the keypad ----
b) Set the current time of “6:45” (PM) to the keypad ------
IMPORTANT NOTE:
1) The r
eal-time-clock stops after power failure, which makes the real-time inhibition loses
its time base. It is necessary to re-program the system’s real-time-clock unless the
keypad is back up with UPS.
2) The keypad gives warning beeps of 3 fast beeps / 5 seconds continuously after
power failure until the real-time-clock is re-programmed.
3) No “after power failure warning beep” will be given if Location 56 is not programmed
with Start/Stop times.
4) Suggest to program the clock every 3-6 months to keep time accuracy; or when time
deviation is found.
CURRENT REAL TIME VALIDATIONLOCATION
(3)
HOURS MIN
UTES
(2)
(1)