User's Manual

5) To program a new Master Code to replace the old one. See “Record A Master Code stated at
“Location 01” for the details.
NOTE:
The keypad will set itself to normal operation mode 1 minute after power-up if the Egress Button is
not pressed and the DAP code is not keyed in. To set keypad back to power-up mode, repeat
procedures 1-4.
SYSTEM REFRESHING WITH “REFRESHING CODE” --- 9 9 9 9
The keypad can be refreshed by cleaning all the programmed old data and set it back to default
values except the Master Code.
REFRESHING CODE VALIDATION
NOTE:
a)
b)
c)

Make sure that system refreshing is really required before entering the refreshing code.
Refreshing takes few minutes. The status LED (amber) keeps flashing during refreshing.
The keypad is back to its default value after refreshing. Re-program of the desired values are
necessary.

DIRECT ACCESS TO PROGRAMMING MODE WITH “DAP” CODE -- 2 8 2 8
In case the Master Code is forgotten, apply the following procedures precisely to set keypad
into programming mode with DAP code:
1)
2)
3)
4)
Switch OFF all the power for 1 minute to ensure that the keypad is fully discharged.
Switch ON power again. The keypad is in Power-up Mode for 1 minute. The buzzer gives
continuous beeps and the Status LED is flashing. This is the only time frame to accept the DAP
code.
Press the Egress Button (the button connecting accross EG IN, (Terminal 9) and (-)GND,
(Terminal 15) once to enable the keypad for accepting DAP code. The power-up beep stops after
the Egress Button is pressed.
Key in the DAP code and validate it with (or ). The Status LED is
ON and the keypad is in programming mode like using Master Code. It is ready to accept new
programming data as long as you like until exit programming mode.
PRESS ONCE
EGRESS BUTTON DAP CODE VALIDATION
Pacifier Tone ON-OFF
7 1
FUNCTION MODE:
0---NO Notification
2---2 Short Beeps
1---1 Second Long Beep
FUNCTION MODE:
0---OFF
1---ON
FUNCTION MODE:
0---OFF
1---ON

FUNCTION MODE
Mode = 1,
ON
7 2
Output Announcer

FUNCTION MODE
7 3
Standby LED Flashing

FUNCTION MODE
Mode = 1,
Flashing ON
Mode = 1
1 Second
Long Beep
Pacifier Tone
8 0
Door Forced Open
Warning & Time
FUNCTION MODE / TIME:
0---OFF
1-999 Seconds

FUNCTION / TIME
Mode = 0,
Door Forced
Open
Warning OFF
8 1
Propped-up Warning &
Time

FUNCTION / TIME
Mode = 0,
Propped-up
Warning OFF
9 0
Egress Delay Warning &
Alarm
CODE 1
-
FUNCTION
MODE:
1---Momentary, No warning
2---Momentary, with
warning
3---Momentary, with
warning + Alarm
4---Hold Contact, No
warning
5---Hold Contact, with
warning
6---Hold Contact, with
warning + Alarm
CODE 2
-
DELAY TIME:
0---No Delay
1-99 Seconds

CODE 1
CODE 2
Mode = 1
Momentary,
No warning
TIME = 0
No Delay
9 1
Door Opening Alarm &
TIMER
ALARM TIME:
0---No Alarm
1-999 Seconds

ALARM TIME
Time = 0,
No Alarm
1 --
2 --
3 --
4 --
9 4
Operation Mode
FUNCTION MODE:

MODE
Mode = 0
Keypad
Mode
1---Server Mode
0---Keypad Mode
9 2
DATA OUTPUT MODE
Wiegand Data Output
Disabled
Wiegand & Data Output
Enabled -- Mode “A”
Wiegand Data Output
Enabled – Mode “B”
Wiegand Data Output
Enabled – Mode “C”
Wiegand Data Output
Mode

DATA OUTPUT MODE
Mode = 1
Disabled
9 3
Wiegand Format

WIEGAND FORMAT
Format = 1
26-Bit
WIEGAND FORMAT
1 --- 26-Bit Wiegand Data
2 --- 34-Bit Wiegand Data
3 --- 37-Bit Wiegand Data