VISITOR CODES (FOR OUTPUT 1 ONLY) (Location 40)
The Visitor Codes are temporary user codes for Output 1 (mainly for door strike in access control).
They can be programmed as “One Time Codes” or “Codes with Time Limit”. The Visitor Codes
will be cleared automatically after use if they are one time codes, or, when the allowed time
expires.
(1) LOCATION
Key in Location
(2) VISITOR ID
--- 50 Visitor IDs for the 50 visitor codes. They are Two-digit numbers
=
(3) VALID PERIOD
The codes in this box MUST be two digits and they represent the time of operation.
--- One Time Code
One Time Code has no time limit but it can only be used for ONCE. It is cleared by the system
- --- Time Limit in Hour(s)
4-8 DIGITS

-


or

-

VISITOR CODE VALIDATIONLOCATION VISITOR ID VALID PERIOD
(5)(4)(3)(2)(1)
The Visitor Code can be set with the valid time limit of 1 Hour to 99 Hours with a two-digit
number of 01 to 99. The visitor code is cleared by the system when the time limit reaches.

-
Clear all the Visitor Codes in Location 40. Please see the Programming example
below for the details.
automatically after use.
(4) VISITOR CODES
NOTE: All Visitor Codes will be cleared after power down to prevent extension/confusion of
their valid time limit.
(5) VALIDATION
Press key once. Two-beep confirms the entry.
The Visitor Codes can be 4-8 digits for Manual Mode code entry.
The Visitor Codes MUST be in the same digit length with the Master Code for Auto Mode code
entry.
The Visitor Codes can not reset Duress Output.
When a new Visitor Code is put in the same Code box, the old code is replaced.
-
34 - Bit
Wiegand Data Output
Bit 1 : Even Parity Bit (bit 2 – bit 17)
Bit 2 – Bit 33 : 32 Bit ID Number
Bit 34 : Odd Parity Bit (bit 18 – bit 33)
-
37 - Bit Wiegand Data Output
Bit 1 : Even Parity Bit (bit 2 – bit 19)
Bit 2 – Bit 36 : 35 Bit ID Number
Bit 37 : Odd Parity Bit (bit 19 – bit 36)
(3) VALIDATION
Press
key once. Two-beep confirms the entry
(1) LOCATION
Key in Location
(2) WIEGAND FORMAT FOR EM CARD & USER CODE
The Wiegand data output is programmable for 26-bit, 34-bit or 37-bit standard format.
- 26 - Bit Wiegand Data Output (Default)
Bit 1 : Even Parity Bit (bit 2 – bit 13)
Bit 2 – Bit 25 : 24 Bit ID Number
Bit 26 : Odd Parity Bit (bit 14 – bit 25)

WIEGAND FORMAT VALIDATIONLOCATION
, or

(2) (3)(1)
WIEGAND DATA OUTPUT FORMAT (Location 93)