Manual
Page 128 of 279 EMS-4 Install and Tuning Guide_Rev 1.6
Choose the air temperature setup from the list and hit the Apply button. This will modify the
settings defined above for the chosen sensor. Please note that some amount of “fine
tuning” to the calibration curve above may still be necessary especially if the EMS is
installed in a “piggy-back” configuration with the factory ECU.