User's Manual

AEO T EC U ser M anu a l
Page 10
Tilt
0x0B
0x00 / 0xFF
tilt event
4.10 CENTRAL SCENE
When activated by configuration parameter #14 the device can perform as a scene controller. Digital + VCC is used to
connect the scene button. The external dry contact will then act as a scene controller with a total of 7 scenes that can
be activated:
• 1 - Contact Pressed 1 time
• 2 - Contact Pressed 2 time
• 3 - Contact Pressed 3 time
• 4 - Contact Pressed 4 time
• 5 - Contact Pressed 5 time
• 6 - Contact held down
• 7 - Contact released
Slow Refresh = 0, A new Key Held Down notification will be sent every 200ms until the key is released.
4.11 Wake Up
Parameter Value
Time
Min Wake Up Interval Seconds 0x000E10
3600s [1 hour]
Max Wake Up Interval Seconds 0xEFF100
15724800s
Default Wake Up Interval Seconds 0x093A80
604800s [1 week]
Wake Up Interval Step Seconds 0x0000F0
240s [4 minutes]
4.12 Battery
1. The 2.90V or more battery voltage corresponds to 100% battery level, and 2. 60V or less corresponds to 0%.
2. If send Battery Get to the device, it will issue Battery Report with battery level to the requester when waked up.
3. If waked up or power on, it will detect battery level, and issue Battery Report 0xFF via Lifeline when battery level is
less than the value of configuration parameter 23 .
4. If the battery level is less than the value of configuration parameter 23 , LED will flash red 3 times for each waked up.
4.13 Indicator
Indicator ID
Property ID
Node Identify
(Green Led)
0x50
On Off Period
0x03
On Off Cycles
0x04
On time within an On/Off period
0x05