User's Manual

AEO T EC U ser M anu a l
Page 5
3.5 How to remove the product
1. Open the housing.
2. Press the tamper on the side of the appliance three times quickly.
3.6 How to manually trigger Wake Up
1. A single click on the button will wake up the device.
2. Repower on will wake up the device.
Note:
The Wake Up period starts when the node issues a Wake Up Notification and it ends either 10 seconds after the last
received/transmitted frame or at the reception of a Wake Up No More Information Command by the Wake Up
destination.
3.7 How to factory reset
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used
when the primary controller is inoperable.
Once Cover is removed and the tamper switch is tripped, push the tamper for 5 seconds until the RED LED blinks once.
Then release tamper and push it again for 5 seconds while the RED LED is blinking until the GREEN LED blinks once.
3.8 Safety Warning for Batteries
The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of
different charging level or different brands.
3.9 Product Usage
Once installed the sensor will report "open" and "close" status changes to a central Z-Wave controller using notification
commands. Additionally, the sensor can directly control other devices using association group 2. Using configuration
commands the source of "open" and "close" events can be chosen between the internal magnet detector or external
dry contact connected via the screw terminal. The device is protected by a tamper switch.
Tilt detection
The tilt detection allows reporting the way a window is opened. This is accomplished using the command class "binary
sensor - tilt-type". The tilt function has 3 modes (mode 1 by default):
Mode 0: turn off the tilt function
Mode 1: Enable tilt function. It needs to be used with magnets. In case the magnet is far away and the tilt angle of the
product is greater than 5 degrees, the tilt event is triggered. In case the magnet is near, the tilt event is released.
Mode 2: Enable tilt function. It can be used alone, but need to identify the current installation location. When this mode
is configured or powered on (mode 2), it will enter the identification mode and the green light will flash. The product
needs to stand still for 3-8 seconds. If the recognition fails, the red light will be on, and the tilt function is not available. It
needs to be recognized again. If the recognition is successful, the green light will be on.In case the tilt angle of the product
is greater than 5 degrees, the tilt event is triggered. In case the tilt angle of the product is less than 5 degrees, the tilt
event is released