User's Manual

AEOTEC User M anual
Page 6
4 SOFTWARE FUNCTION DEFINITION
4.1 User Behavior Interaction
User behavior
Out of the Z-Wave network
In the Z-Wave network
Power OFF
Cut the power.
Cut the power.
Power ON
Send Inclusion Requests for SmartStart
Learn Mode.
LED will flash red 5 times, which means it s
out of the Z-Wave network.
If gateway is adding the device succeeds
through SmartStart, LED will light up green
for 2 seconds
If Adding fails, LED will off. Device will
auto-reset and then activate SmartStart
Learn Mode again.
Send Wake Up Notification.
LED will become flash green once, and
device will wake up for 15 seconds.
Detected water leakage
state change
LED will flash red once.
Trigger Association function.
Refer to Section 4.7 and 4.14 for details
about Association function.
LED will flash red once.
Click tamper switch once
1.Reserved
LED will flash green once.
2.Exit Classic Inclusion Learn Mode:
If tamper switch is clicked again during the
Classic Inclusion Learn Mode, the Classic
Learn Mode will exit. LED will turn off.
Device will auto-reset and then activate
SmartStart Learn Mode again.
1.Issue Wake Up Notification and stay
awake for 15 senconds unless put to sleep
by Wake Up No More Information frame.
LED will flash green once.
2.Exit Classic exclusion Learn Mode:
If tamper switch is clicked again during the
Classic exclusion Learn Mode, the Classic
Learn Mode will exit. LED will turn off.
Click tamper switch twice
Reserved
Start a link test with controller (When
activated by configuration parameter #4).
If success, LED will blink green two times
If failure , LED will blink red two times
Click tamper switch three
times quickly
1.Send Node Info for Adding.
LED will blink green and red for 30s until it
is added into the network.
If Adding succeeds, LED will light up green
for 2 seconds
If Adding fails, LED will turn off. Device will
auto-reset and then activate SmartStart
Learn Mode again.
2.Exit Classic Inclusion Learn Mode:
If tamper switch is clicked again during the
Classic Inclusion Learn Mode, the Classic
Learn Mode will exit. LED will turn off.
Device will auto -reset and then activate
SmartStart Learn Mode again.
1. Send Node Info for Removing.
LED will blink green and red for 30 seconds
until it is removed from the network.
If Removing succeeds, LED will light up red
for 3 times.
If Removing fails, LED will turn off.
2.Exit Classic exclusion Learn Mode:
If tamper switch is clicked again during t he
Classic exclusion Learn Mode, the Classic
Learn Mode will exit. LED will turn off.
Press and hold tamper switch
for 5 seconds
Factory Reset.
push the tamper for 5 seconds until the RED
LED blinks once. Then release tamper and
push it again for 5 secon ds while the RED
LED is blinking until the GREEN LED blinks
once.
Factory Reset.
push the tamper for 5 seconds until the RED
LED blinks once. Then release tamper and
push it again for 5 seconds while the RED
LED is blinking until the GREEN LED blinks
once.
The device will issue a Device Reset Locally
Command via its Lifeline to notify the
Lifeline destination that the device has been