User manual
7
5. Technical data
4. Technical data
Input connections
input
Electronically balanced line input
Unbalanced jack connection also possible
Combo socket, XLR + jack ¼” (6.35 mm)
Nominal input voltage: 1 V (0 dBV)
Min. input voltage:
Combi Sub 12: 360 mV (–9 dBV)
Combi Sub 15: 400 mV (–8 dBV)
Max. input voltage: 9 V (+19 dBV)
Input impedance: 20 k
Equivalent input noise voltage (A-weighted):
6.5 µV (–104 dBV)
link
XLR output, directly connected to input
clip
indicator
Headroom 6 dB
Active crossover
Filter type
Butterworth lowpass, 12 dB/oct.
Crossover
frequency
Adjustable, 70 – 200 Hz
Notch filter
Notch
frequency
Adjustable, 50 – 300 Hz
Notch
attenuation
-14 dB
Bandwidth
0.7 octaves between –6.5 dB points
Notes
Switchable
Power
Power amp
Combi Sub 12: 200 W / 8 (1% THD)
Combi Sub 15: 250 W / 8 (1% THD)
Discrete bipolar transistor output
Residual noise (A-weighted):
260 µV (–72 dBV)
Dynamic range (A-weighted):
104 dB
Mains power
Mains voltage (depending on model):
100, 120, 230, or 240 V AC, 50–60 Hz
Power consumption:
Combi Sub 12: max. 500 W
Combi Sub 15: max. 600 W
Mains fuse
Size: 5 x 20 mm
Rating:
For 230 and 240 V models: T 3.15 A L / 250 V
For 100 and 120 V models: T 6.3 A L / 250 V
General
Distortion
(electrical)
THD + N < 0.1 % at 25 W / 8
Signal
processing
Subsonic filter, RMS limiter
Limiter
threshold
Combi Sub 12: 160 W / 8
Combi Sub 15: 220 W / 8
Speaker
system
Combi Sub 12: 300 mm (12”) woofer
Combi Sub 15: 380 mm (15”) woofer
Bass reflex enclosure
Cabinet
18 mm (0.71“) birch plywood
M20 thread for speaker stand on top side
Finish
Waterbased acrylic, black spatter finish
Dimensions and weight
Dimensions
Combi Sub 12:
430 mm (16,92“) high
490 mm (19,29“) wide
350 mm (13,77“) deep
Combi Sub 15:
490 mm (19.29“) high
560 mm (22.05“) wide
440 mm (17.32“) deep
Weight
Combi Sub 12: 19,55 kg (43,1 lbs)
Combi Sub 15: 29 kg (64 lbs)
NOTES
R
ated conditions:
Input signal: 100 Hz sine, nominal input voltage applied
C
rossover (frequency) control fully clockwise.
N
otch filter off.
L
evel adjusted such that the rated output power is obtained
if the limiter is disabled (L
evel in center position
approximately).
Signal voltages stated as RMS values.
0 dBV corresponds to 1 V RMS.
M
in. input voltage: Input voltage required for rated output
power (without limiter) with l
evel fully clockwise
M
ax. input voltage: Input voltage that does not cause more
than 1% THD+N, suitable control settings provided
T
HD + N: Total harmonic distortion + noise, with input and
output levels 10 dB below rated conditions.
E
quivalent input noise voltage: Noise voltage at speaker
output divided by gain of amplifier at 100 Hz. Control
settings as stated under rated conditions. Measurement
range: 20 Hz – 20 kHz. Input shorted.
R
esidual noise: Output noise when the level control is set to
minimum.
D
ynamic range: Ratio of nominal output voltage to residual
noise voltage
Specifications and appearance subject to change without
notice.