AerAtron Ceiling fans User Manual & Technical Specifications Models: e502 & e503 Australian edition 2011
AerAtron >> Silent Efficiency Instructions .....................................................................................................................................................3 General precautions ...........................................................................................................................................3 Location and installation requirements for your fan..........................................................................................
AerAtron >> Silent Efficiency Instructions Thank you for choosing an Aeratron™ Ceiling Fan. You have chosen the best! We are confident that your new ceiling fan will provide many years of enjoyment. General precautions Please read and follow these instructions carefully, and be mindful of all warnings shown throughout this manual. This fan must be installed by a licensed and qualified electrician according to local authority regulations.
AerAtron >> Silent Efficiency Ensure ceiling joists are sound and of adequate size and strength to support a 35Kg (77lb) load. To reduce the risk of fire, electrical shock or personal injury, ensure that the fan mounting bracket is supported directly from the building structure. DO NOT mount to an outlet box. The mounting bracket must be firmly screwed to a load bearing structure e.g. a concrete ceiling, steel structure or timber frame.
AerAtron >> Silent Efficiency Unpacking your fan Unpack your fan and check the contents. Do not discard the carton. If warranty replacement or repair is ever necessary, the fan should be returned in the original packaging. Examine all parts.
AerAtron >> Silent Efficiency Checking ceiling condition and preparing for fan installation Before commencing installation, turn off electricity supply at the main power box. Disconnect power by removing fuse or turning off circuit breaker before commencing work. Installation mounted to Ceiling Joist Install mounting bracket to ceiling joist using the screws and washer provided. The mounting plate should be able to hold a weight of at least 18kgs.
AerAtron >> Silent Efficiency NOTE: Installation of multiple fans using independent transmitter require “CODE MATCH” before installing the receiver, see page #13.
AerAtron >> Silent Efficiency Make LIVE, GROUND and NEUTRAL connections from Mains Power (House) to Terminal Block. Make LIVE, GROUND and NEUTRAL connections from Remote Control Receiver to Terminal Block. Plug the 9‐Pole plug connector from the DC Motor into the 9‐Pole plug connector from the Receiver.
AerAtron >> Silent Efficiency Attaching Fan Motor Housing to Motor Assembly Line up fixing hole in Motor Housing with screw hole in chassis and install screw Install motor housing using a clockwise Bayonet action Ensure that Fan Motor Housing fixing point with hole (not bayonet slot) is aligned with chassis arm from which fixing screw was removed (see page 6).
AerAtron >> Silent Efficiency Fan Blades and Middle Piece Assembly ! CONSTANTLY HANDLE FAN WITH CARE AT ALL TIMES TO AVOID DAMAGING THE FAN/SURFACE ! e502 Place e502 Hub Upper onto a clean working area. Line‐up the three mounting holes in the e500 Fan Blade with the two screw boss and hole in the Hub Upper.
AerAtron >> Silent Efficiency ! CONSTANTLY HANDLE FAN WITH CARE AT ALL TIMES TO AVOID DAMAGING THE FAN/SURFACE ! e503 Place e503 Hub Upper onto a clean working area. Line‐up the three mounting holes in the e500 Fan Blade with the two screw boss and hole in the Hub Upper.
AerAtron >> Silent Efficiency Fan Blades to Shaft Assembly Pivot Screw Rotate Screw Cover to hide screw head. (Note: Rotating the Screw Cover will prevent Pivot screw from falling out should it become loose.
AerAtron >> Silent Efficiency Remote Control Set‐up Code match your transmitter and receiver Note: receiver itself does not need to set DIP switch Remote Control Code Setting Set your Dip Switch to control individual fan(s) (one per fan handset) or chose same code setting for up to 16 fans within a 7m radius Speed Up 1‐2‐3‐4‐5‐6 Down 6‐5‐4‐3‐2‐1 To start the fan press speed button To change speed of fan press or (indicated by a short buzzer sound) LCD indicates maximal speed (max) On/Off Press the butt
AerAtron >> Silent Efficiency Technical specifications e503 and e502 Colour: white/ silver/ black Remote control: Hand Held, RF Dimensions: e502 as e503 Operating speed (rpm)/ Power Usage (Watt) e503 Speed 1: 51 rpm/ 3.8 W Speed 2: 70 rpm/ 4.5 W Speed 3: 103 rpm/ 7.5 W Speed 4: 119 rpm/ 9.5 W Speed 5: 139 rpm/ 13.6 W Speed 6: 158 rpm/ 18 W e502 Speed 1: 52 rpm/ 3.9 W Speed 2: 73 rpm/ 4.5 W Speed 3: 113 rpm/ 7.7 W Speed 4: 131 rpm/ 9.6 W Speed 5: 153 rpm/ 13.6 W Speed 6: 177 rpm/ 18.
AerAtron >> Silent Efficiency Sloped Ceiling IF THERE ARE ANY PROBLEMS DURING INSTALLATION OF THE FAN, THE INSTALLER MUST CONTACT THE AERATRON HELP LINE BEFORE LEAVING THE SITE: SWISS PRECISION +61 410 465 228 Installation - Operation – Maintenance - Warranty 15
AerAtron >> Silent Efficiency Care & Cleaning Regular cleaning of the Aeratron Ceiling fan blades and fan motor housing is the only maintenance that is needed. Due to the self‐balancing design, a large build up of dust on blades may only in extreme cases create an imbalance, causing the blade to wobble during use. This is likely to be more apparent on fans with a extension rod. Regular cleaning of the blade is recommended to prevent dust from building up. 1.
AerAtron >> Silent Efficiency a couple of centimetres is quite OK and does not suggest that the fan will fall down. The Aeratron fan is mounted securely on a metal Hanger Bracket with rubber cushioning and a ball joint to allow free movement. Please note that due to manufacturing variations not all Aeratron ceiling fans are exactly the same ‐ some may move more that others. Note: Excessive wobble can be caused by the Drive Shaft not being positioned vertically.
AerAtron >> Silent Efficiency Transfer of Warranty. If the dwelling where the fan or remote control is installed changes hands, the balance of the warranty passes to the new owner, providing the original bill of sale for the product is retained by the new owner. Warranty for the fan does not cover damage to the fan if it is moved from one dwelling to another during the warranty period. The warranty is voided in total if the product is sold as second hand goods. The following is NOT covered by warranty. 1.
AerAtron >> Silent Efficiency WARRANTY PHONE NUMBER +61 93656470 (AUSTRALIA ONLY 9am to 5pm Aest) Please Note: When phoning for warranty you will require the following information; date of purchase; model and colour of the fan. The installing electricians details may also be required.
AerAtron >> Silent Efficiency Thank you! Your AerAtron team… Australian edition 2011.