Instruction manual condensation dryer DH 10 / DH 20 AERIAL GmbH Instruction manual Condensation dryer DH 10 / DH 20 AERIAL GmbH - Oststraße 128 - 22844 Norderstedt - Germany Tel.: 0049 40 / 52 68 79 0 - Fax 0049 40 / 52 68 79 20 - e-mail: info@aerial.
Instruction manual condensation dryer DH 10 / DH 20 AERIAL GmbH Index 1 General advice 2 2 Design of equipment and mode of functioning 2 3 Safety 3 4 Installation and transport 3 5 Electrical connection 4 6 Operation 4 6.1 putting into operation 4 6.2 hygrostat control 4-5 6.3 condensate outlet 5-6 6.
Instruction manual condensation dryer DH 10 / DH 20 AERIAL GmbH 1 General advice You have bought an air dryer from AERIAL thus deciding for a proven quality product. If nevertheless complications should occur, you will find some advice hereinafter how to eliminate such difficulties as quickly as possible. Attention! ¾ ¾ ¾ ¾ ¾ Immediately after receipt, you should check your air dryer for transport damage! In the case of damage, you should inform the forwarding agent, parcel service, post office etc.
Instruction manual condensation dryer DH 10 / DH 20 AERIAL GmbH 3 Safety The condensation dryers AD 520 and AD 620 are furnished with protective devices. The devices were subjected to a safety examination. Dangers threaten in the case of operating error or abuse - for the user. - for the machine and other real values. - for the efficient work of the machine.
Instruction manual condensation dryer DH 10 / DH 20 AERIAL GmbH 5 Electrical connection Before connecting the air dryer, the following items must be checked: 9 Does the mains voltage coincide with the voltage of the appliance? 9 Adequate fusing of socket and supply system? 9 Has the required residual-current-operated circuitbreaker (r.c.c.
Instruction manual condensation dryer DH 10 / DH 20 ¾ AERIAL GmbH The marker of the knob points at position "max": the device is in continuous operation Attention! The marks at the rebound curve and the humidity values mentioned above are to be seen as reference values only. The hygrostat of the air dryer and a hygrometer located inside the room to be dried most probably will not indicate the same values.
Instruction manual condensation dryer DH 10 / DH 20 AERIAL GmbH Attention! ¾ ¾ ¾ 6.4 The end of the hose must be situated lower than the beginning of the hose (runoff socket)! The hose must never be bent! No objects must be placed onto the hose! Automatic defrosting During air drying, ice may form at the evaporator. The volume of ice depends on the ambient conditions prevailing in the room to be dried. The air dryer is equipped with an automatic airdefroster.
Instruction manual condensation dryer DH 10 / DH 20 AERIAL GmbH 7 Technische Daten Range of application Supply voltage, frequency Safety class 1 acc. to VDE 0106 T1 Degree of protection IP23 acc. to DIN 40050 air flow Noise level dimensions (width/height/depth) weight refrigerant Warranty Fusing Protection in swimming baths DH 10 +5 to +32°C, 40 to 95 %r.h. 230V, 50Hz 160 m³/h 42 dB(A) 400 mm / 550 mm / 400 mm 24 kg 275 g R134a 24 months from date of purchase 6A r.c.c.b. Performance data acc.
Instruction manual condensation dryer DH 10 / DH 20 AERIAL GmbH 8 Trouble shooting trouble The dehumidifier shows a bad and/or no drying capacity. The automatic circuit breaker of the building disturbs the voltage supply to the device. Pos. Cause 1 The humidity in that room is lower than 40% r.h. . 2 The air filter is soiled 3 The temperature in that room is lower than +15°C. 4 A mistake in the cooling circuit of the dryer is possible. The safeguard of the building is too weak.
Instruction manual condensation dryer DH 10 / DH 20 That dehumidifier is frozen at the evaporator very strong. You can see an ice block. from Serie July 2003 AERIAL GmbH 11 The water tank is full or is not placed correct in the device The red lamp does light up simultaneously. The watercollecting tank must be emptied and must be inserted correctly again. The bucket must be put into the device with the swimmer ahead.
Instruction manual condensation dryer DH 10 / DH 20 The dryer does not achieve the humidity adjusted at the hygrostat and/or does not switch itself off via the hygrostat. AERIAL GmbH 15 A condensation dryer can achieve The hygrostat is adjusted onto a value below 45% r.h.. - depending on environmental conditions - at a minimum a value from 40 to 45% r.h. . Put the builtin hygrostat on an attainable value (e.g. approx. 50%r.h.), with it that dehumidifier punctual may switch off.
Instruction manual condensation dryer DH 10 / DH 20 AERIAL GmbH 9 Repair and maintenance Attention! When performing any repair or maintenance, the general safety rules and provisions must be adhered to! In normal operation, the air filter should be cleaned regularly. It recommends to exchange the air filter 2x in the year. Further maintenance operations at the dehumidifier are not necessary. In order to safeguard a perfect operation of the air dryer, the appliance should be cleaned at regular intervals.
Instruction manual condensation dryer DH 10 / DH 20 AERIAL GmbH 11 Bezeich Denotation of the most important components DH Pos. 1 2 3 4 5 7 8 9 10 11 Denotation Hygrostat knob Main cable with plug (ca. 2,5 mtr.) cover compressor condenser / evaporator-unit Water tank with swimmer Air filter Hygrostat Timer Micro switch Pos.
Instruction manual condensation dryer DH 10 / DH 20 AERIAL GmbH 13 Manufacturer declaration (EG-directive 89/392/EWG) (EG-directive 89/336/EWG) (EG-directive 73/ 23/EWG) supplier: AERIAL GmbH - Systeme zur Luftbehandlung Oststraße 128, D-22844 Norderstedt Product description: Luftentfeuchter DH 10 / DH 20 Rated capacity: 10 l/24h / 20 l/24h The product described above is an ambient air dryer ready for connection. Related standards: EN 292 EN 50081-1 EN 50082-1 EN 60335-2-40 Norderstedt, 01.07.