A100 OPERATING MANUAL
© 2002 Design, 2012 Doc. No. 12-7271-r01 (4/25/12)
PO2 during Deco
When PO2 reaches 1.60, the Audible will sound during which the PO2 value with icon will flash in place of Stop Time.
> After 10 seconds, the PO2 value with icon will alternate with Stop Time once each minute* (Fig. 57).
*PO2 will be displayed flashing for 10 seconds, then Stop Time will be displayed for 50 seconds once each minute until PO2
decreases below 1.60, then PO2 will not be displayed.
HIGH O2
Warning >> at 80 to 99% (240 OTU).
Alarm >> at 100% (300 OTU).
When O2 reaches the Warning level, the O2 value with O2% icon will flash in place of Depth (Fig. 58), then Depth will be
restored.
No indication (Up Arrow) is given to ascend.
If O2 reaches the Alarm level, the graphic UP, Up Arrow icon, and the O2 value with O2% icon (in place of Depth) will flash
(Fig. 59). After 10 seconds, Depth will be restored, the graphic UP with Up Arrow icon will remain on flashing until on the
surface, and the graphic O2 will replace DTR (Fig. 60).
B (< 2 sec) to access ALTs which are similar to No Deco.
High O2 during Deco
When O2 reaches the Warning Level, the O2 value with O2% icon will flash in place of Depth (similar to Fig. 58), then Depth
will be restored.
No indication (Up Arrow) is given to ascend.
If O2 reaches the Alarm level, the graphic UP (in place of Stop Depth), Up Arrow icon, and the O2 value with O2% icon (in
place of Depth) will flash, Stop Time will display 3 dashes - : - - (Fig. 61). After 10 seconds, Depth will be restored, the graphic
UP with Up Arrow icon will remain on flashing until on the surface, and the graphic O2 will replace Stop Time.
The full TLBG
remains on solid as a reminder of Deco.
B (< 2 sec) to access ALTs which are similar to Deco.
High O2 on Surface
Upon ascent to 2 FT (0.6 M) for 1 second (surfacing), the Surface Main screen is displayed (similar to Fig. 62). During the first
10 minutes, access to the Surface ALTs is allowed with other modes and screens blocked until the 10 minutes elapse.
> If O2 is 100%, the value with O2% icon will flash on the Main in place of Surface Interval (SI) time until 10 minutes elapse,
then it will alternate with SI until it is < 100% when SI will be restored.
> If you surface due to 100% O2 without having completed the Deco obligation, operation will enter VGM after 5 minutes.
Fig. 57 - PO2 ALARM
(after 10 sec, Deco)
alternate
with PO2
Fig. 58 - O2 WARNING
(during 10 sec)
Fig. 59 - O2 ALARM
(during 10 sec, No Deco)
Fig. 60 - O2 ALARM
(after 10 sec, No Deco)
Fig. 61 - O2 ALARM
(during 10 sec, Deco)
Fig. 62 - SURFACE MAIN