A300/A300 XT OPERATING MANUAL A300 with FREE DIVE MODE A300 XT with ANALOG PRESSURE GAUGE DIVE COMPUTER OPERATING MANUAL © 2002 Design, 2012 1 Doc. No.
A300/A300 XT OPERATING MANUAL CONTENTS NOTICES................................................................................................3 GAUG OP MODE.................................................................................34 SURFACE MODES..........................................................................35 DIVE MODES...................................................................................37 FEATURES AND FUNCTIONS.............................................................
A300/A300 XT OPERATING MANUAL Welcome to AERIS and THANK YOU for choosing the A300 / A300 XT NOTICES COPYRIGHT NOTICE This operating manual is copyrighted, all rights are reserved. It may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine readable form without prior consent in writing from AERIS/2002 Design. A300 / A300 XT Operating Manual, Doc. No.
A300/A300 XT OPERATING MANUAL FEATURES AND FUNCTIONS (Also see Dive Mode Features, page 21.) © 2002 Design, 2012 4 Doc. No.
A300/A300 XT OPERATING MANUAL DISPLAY ICONS - - - Time - - - Safety Stop - - - Surface Interval - - - Deco Stop - - - Plan Mode - - - Go Down to Stop - - - Go Up to Stop - - - Go Up Icons: SET = FLY = Battery = O2% = CF = Z+ = DSAT = M, FT = MAX = Setting Mode Time to Fly Low Voltage % of O2 saturation Conservative Factor is on Algorithm selected Algorithm selected Depth units Max Depth FO2 = # = SAT = PO2 = TAT = SS = M, FT = O2 = value is FO2 setting Dive recently conducted
A300/A300 XT OPERATING MANUAL OVERVIEW The A300 model features FREE Dive mode as well as NORM, TECH, and GAUG modes. The A300xt model features a Tank Pressure alarm (actuated by an reed switch) for an analog pressure gauge mounted in the same console as the dive computer module. NORM mode is intended for the casual diver who plans to use a single gas and does not yet wish to configure the numerous settings and alarms, many are factory set at predetermined fixed values.
A300/A300 XT OPERATING MANUAL AUDIBLE ALARM While operating in NOR, TEC, or GAU mode, the Audible will emit 1 beep per second for 10 seconds when alarms strike, unless it is set Off. During that time, the Audible can be acknowledged and silenced by pressing the S button (less than 2 seconds). An LED Warning Light, on the housing, is synchronized with the Audible and flashes as the Audible sounds. It will turn Off when the Alarm is silenced.
A300/A300 XT OPERATING MANUAL POWER SUPPLY • Battery >> (1) 3 vdc, CR2450, Lithium. • Shelf life >> up to 5 years. • Use life >> 100 dive hours if (1) 1 hour dive per dive day up to 300 dive hours if (3) 1 hour dives per dive day. • Use life >> 300 dive hours if (2) 1 hour dives per dive day. • Replacement >> by user (annual recommended). BATTERY STATUS INDICATION a • Warning >> icon on solid (Fig. 4a) when < 2.75 volts, battery change recommended. • Alarm >> icon on flashing (Fig. 5) when < 2.
A300/A300 XT OPERATING MANUAL NORM/TECH SURFACE MODES © 2002 Design, 2012 9 Doc. No.
A300/A300 XT OPERATING MANUAL NORM/TECH SURFACE MODE The SURF MAIN screen of the mode selected will remain on display for 10 minutes during which time the unit will enter that type Dive Mode upon descent to 5 FT (1.5 M) for 5 seconds. The unit will enter Post Dive Surface Mode for that Mode upon ascent to 2 FT (0.6 M) for 1 second and display the Surface Main with the Surface Mode (clock/wave) icon flashing.
A300/A300 XT OPERATING MANUAL NORM/TECH SURF ALT 3 (only if Nitrox, no screen if Air), information includes (Fig. 11): > Current O2% saturation with icon. > Current FO2 set for Gas 1 with FO2, Gas 1, & NX icons. > Current PO2 alarm value set for Gas 1 with icon, fixed at 1.40 if NORM. • • • • A (< 2 sec) to step forward to FLY. M (< 2 sec) to step back to ALT 2. 10 sec, or M (2 sec), revert to Main. S (press) to activate Backlight. Fig.
A300/A300 XT OPERATING MANUAL PDPS, information includes (Fig. 15, 16): > Z+ (or DSAT), CF, NX icons, if they apply. > Plan Depth value with FT (or M) icon. > FO2 set for Gas 1 (xx%) with FO2 icon if Nitrox, blank if Air. > NDC (No Deco) or O2 limit (hr:min) with mode icon (wave/clock/profile, with O2 if OTL. > Gas (tank) 1 icon. > Plan mode icon (wave/clock/profile). • S (2 sec), while viewing the first screen, to step back to Plan Lead-in.
A300/A300 XT OPERATING MANUAL Log > > > > > > • • • • Data 3, information includes (Fig. 21): Z+ (or DSAT), CF, DS, NX icons, if they apply. Max Depth with FT (or M) and MAX icons. Elapsed Dive Time (hr:min) with wave/clock (EDT) icon. TLBG with max segment flashing, others fixed up to end of dive accumulation. Blank if GAUG or VGM. VARI, max Ascent Rate sustained for 4 sec. LOG icon. Log Data 4 (only if Nitrox), information includes (Fig. 22): > O2% with icon, at end of dive.
A300/A300 XT OPERATING MANUAL SETTING NORM/TECH FO2 AND PO2 ALARMS NORM is for use with only 1 Gas for which FO2 can be set for Air, and 21 to 100% Nitrox. The PO2 Alarm is fixed at 1.40 with a Warning fixed at 1.20. TECH is for use with up to 3 Gas’ each of which FO2 can be set for Air, and 21 to 100% Nitrox. Each Gas has a separate PO2 Alarm which can be set from 1.00 to 1.60 with a Warning fixed at 0.20 less. There is no FO2 50% Default setting like previous AERIS Nitrox dive computers.
A300/A300 XT OPERATING MANUAL TECH SET GAS 2 (3 similar), information includes (Fig. 29): > SET, FO2, Gas (tank) 2 icons. > CF, Z+ (or DSAT) icons, if they apply. > Graphic AIR (or OFF*) flashing, or . . Max Depth allowed with FT (or M) and MAX icons. . . FO2 (numeric) value flashing. Since there are only 2 digits, 100% is displayed as 00. . . PO2 Alarm value with PO2 icon. *OFF will prevent that Gas from being displayed as a switch option during dives. Fig.
A300/A300 XT OPERATING MANUAL SET EDT ALARM, information includes (Fig. 33): > SET icon. > Graphic OFF (or ON) flashing, with Time value (hr:min) last set with wave/clock icon solid. • A (< 2 sec) to step through the selections OFF, ON, and SET. • M (< 2 sec) to step back through the selections. • S (< 2 sec) to save the selection and access Set TLBG Alarm if OFF or ON is saved (if TECH), or revert to Set ALM if OFF or ON is saved (if NORM), or flash the Time digits if SET is saved.
A300/A300 XT OPERATING MANUAL SET WATER TYPE (TECH only), information includes (Fig. 37): > Graphic H2O with SET icon. > Graphic FRESH (or SEA) flashing. • • • • A or M (< 2 sec) to toggle between FRESH and SEA. S (< 2 sec) to save the setting and access Set Units. S (2 sec), if the Set Point is not changed, to step back to Set UTL Lead-in. 2 minutes, or M (2 sec), revert to Main. Fig. 37 - SET WATER TYPE SET UNITS, information includes (Fig. 38): > Graphic UNIT with SET icon.
A300/A300 XT OPERATING MANUAL SET ALGORITHM, information is to include (Fig. 43): > Graphic ALGO with SET icon. > Z+ (or DSAT) icon flashing. • • • • A or M (< 2 sec) to toggle between Z+ and DSAT. S (< 2 sec) to save the setting and access Set Sampling Rate if NORM, or Set Conservative Factor if TECH. S (2 sec), if the Set Point is not changed, to step back to Set Safety Stop. 2 minutes, or M (2 sec), revert to Main. Fig.
A300/A300 XT OPERATING MANUAL SET DATE FORMAT, information is to include (Fig. 48): Date Format is used to establish the position on the screen of Month (M) relative to Day (D), which one is displayed on the left and which one on the right. > Graphic DATE with SET icon. > Graphic M.D (or D.M) flashing. • • • • A or M (< 2 sec) to toggle between the M.D and D.M. S (< 2 sec) to save the setting and access Set Hour Format. S (2 sec) to step back to Set TME Lead-in. 2 minutes, or M (2 sec), revert to Main.
A300/A300 XT OPERATING MANUAL HISTORY MODE History is a summary of data recorded during all NORM, TECH, and GAUG dives conducted. If no dives have been recorded, the graphics NONE YET will be displayed upon accessing screen 1, other screens will not be available. History 1, information includes (Fig. 52): > Total dive hours recorded (up to 9999) with clock icon. > Total dives recorded (up to 9999) with # icon. > HIST icon. • • • • S (< 2 sec) to access History 2. A (< 2 sec) to step forward to ID-SN.
A300/A300 XT OPERATING MANUAL DIVE MODE FEATURES © 2002 Design, 2012 21 Doc. No.
A300/A300 XT OPERATING MANUAL WET ACTIVATION OF DIVE MODE The unit is configured with contacts that will automatically activate Dive Mode when the space between the contacts is bridged by a conductive material (immersed in water) and it senses a Depth of 5 FT (1.5 M). The contacts are the metal pins of the PC Interface Data Port and the stems of the buttons. SMARTGLO® BACKLIGHT The unit is configured with a sensor that measures the intensity of ambient light.
A300/A300 XT OPERATING MANUAL CONSERVATIVE FACTOR (CF) When the CF is set On, the NDLs which are based on the algorithm selected and used for Ni/O2 calculations and displays relating to Plan and DTR, will be reduced to the values available at the altitude level that is 3,000 feet (915 meters) higher. Refer to the NDL charts in the back of this manual.
A300/A300 XT OPERATING MANUAL O2 Time Remaining (OTR) During Nitrox operation, O2 accumulation during a dive, or 24 hour period, is displayed on an Alternate screen as a percent of O2 saturation allowed per dive or per day (Fig. 60a). Max allowed is 300 OTU (= 100%). a When time remaining before reaching the O2 limit becomes less than NDC, calculations for that Depth will be controlled by O2 and OTR will be displayed as DTR on the Dive Main (Fig. 61a). Fig. 60 - NO DECO ALT 3 (current % O2) a Fig.
A300/A300 XT OPERATING MANUAL NORM/TECH DIVE MODES Unless noted otherwise, information in this section applies to both NORM and TECH dives. © 2002 Design, 2012 25 Doc. No.
A300/A300 XT OPERATING MANUAL NO > > > > > > > > • • • • DECO MAIN, information includes (Fig. 62) Z+ (or DSAT) icon, algorithm selected. CF icon, if set On (TECH only). Current Depth with FT (or M) icon. DTR (hr:min) with wave/clock/profile (NDC) icon. DS icon, if set On and triggered (TECH only). Gas (tank) 1 icon; one in use (1, 2, or 3 if TECH). NX icon, if FO2 is set for nitrox, blank if Air. TLBG, VARI, if they apply. Fig. 62 - NO DECO MAIN A (< 2 sec) to access ALT 1.
A300/A300 XT OPERATING MANUAL DS ALTs, information #1 >> is similar to No #2 >> is similar to No #3 >> is similar to No #4 >> is similar to No Deco Deco Deco Deco Main. ALT 1. ALT 2. ALT 3. SAFETY STOP MAIN, information includes (Fig. 68, 69) > Z+ (or DSAT) icon, algorithm selected. > CF icon, if set On (TECH only). > Current Depth with FT (or M) icon. > Stop Depth with FT (or M) icon; fixed at 15 FT (4.5 M) if NORM, at value set if TECH. > Stop icon (arrows, bar) with SS icon.
A300/A300 XT OPERATING MANUAL DECO STOP MAIN, information includes (Fig. 71) > Z+ (or DSAT) icon, algorithm selected. > CF icon, if set On. > Current Depth with FT (or M) icon. > Stop Depth with FT (or M) icon. > Stop icon (arrows, bar). > Stop Time (hr:min) with wave/clock/profile/bar (Deco) icon. > Gas (tank) 1 icon; one in use (1, 2, or 3) if TECH. > NX icon, if FO2 is set for Nitrox, blank if Air. > Full TLBG (all segments). • • • • Fig. 71 - DECO STOP MAIN A (< 2 sec) to access ALT 1.
A300/A300 XT OPERATING MANUAL DELAYED VIOLATION 1 (DV1) Once above the Deco Stop Depth for more than 5 minutes, operation will enter DV1 which is a continuation of CV**. **The difference between DV1 and CV is that DV1 causes operation to enter Violation Gauge Mode 5 minutes after surfacing from that dive. The Audible will sound during which the alarm LED and full TLBG will flash. The Down Arrow icon will flash (Fig. 77) until descent is made to below the required Stop Depth. Fig.
A300/A300 XT OPERATING MANUAL VGM Main, information includes (Fig. 81) > Current Depth with FT (or M) icon. > Graphics UP VIO with Up Arrow icon, flashing until on surface. > VARI, while ascending. • • • • A (< 2 sec) to access ALT 1. M (2 sec) to access Gas Switching (TECH only). S (< 2 sec) to silence/acknowledge alarms. S (press) to activate Smartglo® Backlight. Fig. 81 - VGM MAIN (after Audible) > ALTs are similar to Deco, with no TAT or O2 data.
A300/A300 XT OPERATING MANUAL HIGH O2 Warning >> at 80 to 99% (240 OTU). Alarm >> at 100% (300 OTU). When O2 reaches the Warning level, the Audible will sound during which the O2 value with O2% icon will flash in place of Depth (Fig. 86) until the audible is silenced, then Depth will be restored. No indication (Up Arrow) is given to ascend.
A300/A300 XT OPERATING MANUAL TECH DIVE GAS SWITCHING © 2002 Design, 2012 32 Doc. No.
A300/A300 XT OPERATING MANUAL OVERVIEW > Can only switch when a Dive Main screen is displayed. > Cannot switch on surface. > Cannot switch during sounding of alarms. > All dives begin with Gas 1 and default to Gas 1 on the surface. GAS SWITCH PREVIEW, information includes (Fig. 91, 92, 93): > Graphics Go To (meaning switch or change to that Gas). > Graphic AIR with FO2 icon; or if Nitrox FO2 value set (21 to 100%) with FO2 icon and current PO2 level with PO2 and NX icons.
A300/A300 XT OPERATING MANUAL GAUG OP MODE © 2002 Design, 2012 34 Doc. No.
A300/A300 XT OPERATING MANUAL GAUG SURFACE MODE The SURF MAIN screen will remain on display for 10 minutes during which time the unit will enter GAUG Dive Mode upon descent to 5 FT (1.5 M) for 5 seconds. The unit will enter Post Dive Surface Mode upon ascent to 2 FT (0.6 M) for 1 second and display the Surface Main with the Surface Mode (clock/wave) icon flashing. Access to SURF ALT screens is allowed during the first 10 minutes with access to other surface modes/screens blocked until 10 minutes elapse.
A300/A300 XT OPERATING MANUAL FLY, information includes (Fig. 98): > Time to Fly countdown (hr:min) with FLY and clock (time) icons, dashes if no dive yet. • • • • A (< 2 sec) to step forward to Log Lead-in. M (< 2 sec) to step back to ALT 2. 2 minutes, or M (2 sec), revert to Main. S (press) to activate Backlight. Fig. 98 - FLY LOG - shared with NORM/TECH (see page 12). GAUG SET GROUPS - similar to NORM/TECH (see page 13). Sequence >> Set Lead-in >> Set OP MOD >> Set ALM >> Set UTL >> Set TME.
A300/A300 XT OPERATING MANUAL GAUG Dive Run Timer While operating in GAUG Dive mode a Run Timer, that by default is displayed on the Dive ALT 1 screen, can be interchanged with EDT (Elapsed Dive Time) and displayed on the Main with EDT moving to the ALT 1 screen. When the Run Timer is active, it will continue to run in the background during the first 10 minutes on the surface after a dive, then shut off with time reverting to 0:00. GAUG DIVE MAIN, information includes (Fig.
A300/A300 XT OPERATING MANUAL FREE DIVE OP MODE (A300 only) © 2002 Design, 2012 38 Doc. No.
A300/A300 XT OPERATING MANUAL FREE SURFACE MODE FREE dives, which are allowed prior to NORM, TECH, or GAUG dives as well as after NORM or TECH dives, calculate Ni-O2 based upon the NORM/TECH Algorithm selected and a fixed default FO2 of Air. FO2 settings for NORM/TECH dives do not affect calculations for FREE Dives. FREE mode displays NDC Time (on a dive ALT screen) and the TLBG on surface and dive Main screens, and includes a TLBG Alarm that activates when it enters the Caution zone (14 segments).
A300/A300 XT OPERATING MANUAL FREE SURF ALT 2, information includes (Fig. 106): > Time of Day (hr:min) with AM (or PM) icon, no icon if 24 hour format. > Temperature with °F (or °C) icon. > Altitude graphic, if L2 (to L7), blank if Sea level. • • • • A (< 2 sec) to step forward to FLY. M (< 2 sec) to step back to ALT 1. 10 sec, or M (2 sec), revert to Main. S (press) to activate Backlight. Fig.
A300/A300 XT OPERATING MANUAL SET ALM (ALARMS) LEAD-IN, information is to include (Fig. 109): > Graphics Go To and ALM with SET icon. • • • • S (< 2 sec) to access Set EDT Alarm. A (< 2 sec) to step forward to Set UTL Lead-in. M (< 2 sec) to step back to Set CDT Lead-in. 2 minutes, or M (2 sec), revert to Main. Fig. 109 - SET CDT SET EDT ALARM, information is to include (Fig. 110): The FREE mode EDT Alarm is factory set for 30 seconds.
A300/A300 XT OPERATING MANUAL FREE DIVE MODE STRUCTURE Surface Mode at 2 FT (0.6 M) for 1 sec at 5 FT (1.5 M) for 5 sec Dive Mode DIVE MAIN S Interchange EDT & CDT on Main & ALT press Light (Smartglo) < 2 sec Start/Stop Timer 2 sec 2 sec M Reset Timer A < 2 sec ALTs FREE Countdown Timer (CDT) The CDT, which can only be set while on the surface, is by default displayed on the Dive ALT 1 screen.
A300/A300 XT OPERATING MANUAL FREE DIVE ALARMS FREE mode alarms, which are separate from NORM (or GAUG) alarms, sound either 1 or 3 times as 3 beeps then clear. They cannot be acknowledged or silenced. CDT Alarm When a set Countdown Time reaches 0:00, the audible will sound during which time the graphic CD will be displayed with 0:00 (min:sec) flashing on the Main (Fig. 116). If Temperature and EDT are on the Main, CDT replaces them during the audible then they are restored. Fig.
A300/A300 XT OPERATING MANUAL REFERENCE CAUTION: When the procedure provided in this section is used to change the Battery, you must be sure that the case o-ring is not pinched and that the unit is water tight before conducting diving actvities. Pre dive pressure testing by an Authorized AERIS facility is highly recommended. © 2002 Design, 2012 44 Doc. No.
A300/A300 XT OPERATING MANUAL PC INTERFACE The A300 and A300 XT are configured with Data Ports (Fig. 121a, 122a) that enable their attachment to an Interface System capable of connection to a PC through a USB port. a A USB Driver, provided as part of the optional Interface System, must be installed on the PC. The unit will check for an external access request every second while in Surface Mode (NORM, TECH, GAUG, or FREE). Fig. 121 - DATA PORT (A300) Checks are not made if the activation contacts are wet.
A300/A300 XT OPERATING MANUAL CARE AND CLEANING Protect your unit from shock, excessive temperatures, exposure to chemicals, and tampering. Protect the lens against scratches with a Instrument Lens Protector. Small scratches will naturally disappear underwater. • Soak and rinse the unit in fresh water at the end of each day of diving, and check to ensure that the areas around the Low Pressure (Depth) Sensor (Fig. 124a, 125a), PC Interface Data Port (Fig.
A300/A300 XT OPERATING MANUAL Inspection • Closely check all of the sealing surfaces for any signs of damage that might impair proper sealing. • Inspect the buttons, lens, and housing to ensure they are not cracked or damaged. WARNING: If damage or corrosion is found, return your unit to an Authorized AERIS Dealer, and DO NOT attempt to use it until it has received factory prescribed service.
A300/A300 XT OPERATING MANUAL ALTITUDE SENSING AND ADJUSTMENT Prior to the first dive of a series of repetitive dives, Altitude (i.e., ambient pressure) is measured upon activation, then every 15 minutes until a dive is made. > Measurements are only taken when the unit is dry. > Two readings are taken, the second reading 5 seconds after the first. The readings must be within 1 foot (30 cm) of each other to record that ambient pressure as the current Altitude.
A300/A300 XT OPERATING MANUAL TECHNICAL DATA © 2002 Design, 2012 49 Doc. No.
A300/A300 XT OPERATING MANUAL DSAT BASED NDLS (HR:MIN) (IMPERIAL) Altitude (feet) Depth (FT) 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 0 to 3000 3001 to 4000 4001 to 5000 5001 to 6000 6001 to 7000 7001 to 8000 8001 to 9000 9001 to 10000 10001 to 11000 11001 to 12000 12001 to 13000 13001 to 14000 4:20 2:17 1:21 0:57 0:40 0:30 0:24 0:19 0:16 0:13 0:11 0:09 0:08 0:07 0:07 0:06 0:05 3:21 1:43 1:03 0:43 0:31 0:24 0:19 0:15 0:12 0:09 0:07 0:07 0
A300/A300 XT OPERATING MANUAL Z+ BASED NDLS (HR:MIN) (IMPERIAL) Altitude (feet) Depth (FT) 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 0 to 3000 3001 to 4000 4001 to 5000 5001 to 6000 6001 to 7000 7001 to 8000 8001 to 9000 9001 to 10000 10001 to 11000 11001 to 12000 12001 to 13000 13001 to 14000 3:17 1:49 1:05 0:48 0:35 0:26 0:19 0:16 0:12 0:10 0:08 0:07 0:06 0:06 0:05 0:05 0:04 2:30 1:21 0:53 0:37 0:26 0:19 0:15 0:11 0:09 0:08 0:07 0:06 0:0
A300/A300 XT OPERATING MANUAL SPECIFICATIONS CAN BE USED AS • Dive Computer (Air or Nitrox); A300 XT with up to 3 Gases (up to 100% O2). • Digital Depth Gauge/Timer. • Free Dive Gauge/Timer (A300 only). DIVE COMPUTER PERFORMANCE • Dual Algorithm >> Buhlmann ZHL-16c based Pelagic Z+, or DSAT based. • No Deco limits >> closely follow PADI RDP. • Decompression >> in agreement with Buhlmann ZHL-16c and French MN90. • No Deco Deep Stops >> Morroni, Bennett.
A300/A300 XT OPERATING MANUAL SPECIFICATIONS (CONTINUED) BAR GRAPHS: TLBG • No Deco Normal zone (green) • No Deco Caution zone (yellow) • Decompression zone (red) segments 1 to 13 = 5 to 65% allowable tissue loading. 14 to 19 = 70 to 95% allowable tissue loading. 20 = 100% tissue loading.
A300/A300 XT OPERATING MANUAL INSPECTION / SERVICE RECORD Serial Number: ___________________________________________________________________________________________________ Firmware Rev: ___________________________________________________________________________________________________ Date of Purchase: ___________________________________________________________________________________________________ Purchased from: __________________________________________________________________________________
A300/A300 XT OPERATING MANUAL NOTES © 2002 Design, 2012 55 Doc. No.
A300/A300 XT OPERATING MANUAL A300 / A300 XT DIVE COMPUTER OPERATING MANUAL © 2002 Design, 2012 56 Doc. No.