A300/A300 XT OPERATING MANUAL
© 2002 Design, 2012 Doc. No. 12-7255-r01 (5/14/12)
DECO STOP MAIN, information includes (Fig. 71) -
> Z+ (or DSAT) icon, algorithm selected.
> CF icon, if set On.
> Current Depth with FT (or M) icon.
> Stop Depth with FT (or M) icon.
> Stop icon (arrows, bar).
> Stop Time (hr:min) with wave/clock/profile/bar (Deco) icon.
> Gas (tank) 1 icon; one in use (1, 2, or 3) if TECH.
> NX icon, if FO2 is set for Nitrox, blank if Air.
> Full TLBG (all segments).
A (< 2 sec) to access ALT 1.
M (2 sec) to access Gas Switching (TECH only).
S (< 2 sec) to silence/acknowledge alarms.
S (press) to activate Smartglo
®
Backlight.
DECO STOP ALT 1, information includes (Fig. 72) -
> Max Depth with FT (or M) and MAX icons.
> Total Ascent Time (hr:min) with TAT and clock icons.
A (< 2 sec) to access ALT 2.
M (< 2 sec) to step back to Main.
10 sec, revert to Main if A or M is not pressed.
S (press) to activate Smartglo
®
Backlight.
DECO STOP ALT 2, information includes (Fig. 73) -
> Max Depth with FT (or M) and MAX icons.
> EDT (hr:min) with wave/clock icon.
A (< 2 sec) to access ALT 3.
M (< 2 sec) to step back to ALT 1.
10 sec, revert to Main if A or M is not pressed.
S (press) to activate Smartglo
®
Backlight.
DECO STOP ALT 3, information includes (Fig. 74) -
> Time of Day (hr:min) with AM (or PM) icon if 12 Hour.
> Temperature with °F (or °C) icon.
A (< 2 sec) to access ALT 4 if Nitrox, or revert to Main if Air.
M (< 2 sec) to step back to ALT 2.
10 sec, revert to Main if A or M is not pressed.
S (press) to activate Smartglo
®
Backlight.
DECO STOP ALT 4, information includes (Fig. 75) -
> Z+ (or DSAT) icon, algorithm selected.
> O2% accumulated with icon.
> FO2 with icon, value set for Gas in use.
> PO2 value (x.xx ATA) with icon.
> Gas (tank) 1 icon; one in use (1, 2, or 3 if TECH).
> NX icon.
A (< 2 sec) to revert to Main.
M (< 2 sec) to step back to ALT 3.
10 sec, revert to Main if A or M is not pressed.
S (press) to activate Smartglo
®
Backlight.
NORM/TECH CONDITIONAL VIOLATION (CV)
Upon ascent above the required Deco Stop Depth, operation will enter CV during which no off gassing credit will be given,
meaning Deco Stop Time and TAT will not decrease.
The Audible will sound during which the alarm LED will flash. A Down Arrow will also flash (Fig. 76) until descent is made to
below the required Stop Depth, then it is removed.
S (< 2 sec) to silence Audible.
> Other button operations and displays are similar to Deco.
If descent below the required Deco Stop Depth is made within 5 minutes, operation will resume in Deco with off gassing credit
given (Stop Time and TAT will decrease).
Fig. 71 - DECO STOP MAIN
Fig. 72 - DECO STOP ALT 1
Fig. 74 - DECO STOP ALT 3
Fig. 73 - DECO STOP ALT 2
Fig. 75 - DECO STOP ALT 4
Fig. 76 - CV MAIN