TO SET - DIVE TIME REMAINING ALARM
(while in the Surface Mode)
Factory set for 0:00 (minutes), the Dive Time Remaining Alarm can
be set to values between 0:00 and 0:20 (minutes) in increments of 1
minute.
Press Both buttons simultaneously, release when SET: 2 appears.
Press and release the Advance (Front) button, the Units screen ap-
pears with the set point flashing.
Press the Advance (Front) button 11 more times.
The graphic dtr and Alarm and Dive Mode icons appear with the
Dive Time Remaining value flashing (Fig. 34).
Press and hold the Select (Bottom) button to scroll through the
Alarm values.
Press the Advance (Front) button to accept the setting and ad-
vance to Set Max PO2 Alarm, or press and hold Both buttons for 2
seconds to revert to Surface Mode.
Fig. 34 - Set Dive Time Remain-
ing Alarm