F11 OPERATING MANUAL F11 OPERATING MANUAL © 2002 Design, 2013 1 Doc. No.
F11 OPERATING MANUAL CONTENTS NOTICES................................................................................................2 INITIAL ACTIVATION.............................................................................3 FULL LCD..............................................................................................3 SET UTILITIES................................................................................18 Set Units.....................................................................
F11 OPERATING MANUAL INITIAL ACTIVATION AERIS Watch type dive gauges are placed in a Deep Sleep mode prior to being shipped from the factory. The intent is to extend storage life of the Battery for up to 7 years, before the unit is initially placed in service. In this mode, Date and Time are updated as they normally would be. However, they are not displayed. Upon waking the F11 up, the correct Date and USA Pacific Time will be displayed and it will be ready to operate with full functions.
F11 OPERATING MANUAL Welcome to AERIS and THANK YOU for choosing the F11 © 2002 Design, 2013 4 Doc. No.
F11 OPERATING MANUAL GENERAL FEATURES & DISPLAYS © 2002 Design, 2013 5 Doc. No.
F11 OPERATING MANUAL INTERACTIVE CONTROL CONSOLE The Interactive Control Console consists of four Control Buttons that allow you to select mode options and access specific information. They are also used to enter Settings, operate the Backlight, and access additional screens of information. Throughout this manual they will be referred to as the M, S, L, and A buttons.
F11 OPERATING MANUAL Situation that will sound (1, 2, or 3) sets of (1 to 10) .125 second beeps • Depth Alarms DA 1 to DA 6, if set On. backlight To turn the Backlight On, press and release the Light button (< 2 seconds). The Backlight will remain On for the Duration time set (a Set Utilities selection) unless you turn it Off during that time. • The Backlight will come On (even if set OFF) when alarms strike and remain On until turned Off or automatically after 10 seconds .
F11 OPERATING MANUAL WATCH MODE © 2002 Design, 2013 8 Doc. No.
F11 OPERATING MANUAL WATCH TIME Main Time is the default screen displayed while in Watch Mode. In addition to Time of Day and Date, Day of the Week will be displayed which you can interchange with Dual Time which is an hour based differential that you can set. You can choose to have Watch Main Time displayed with Day of the Week or with Dual Time (such as when visiting a location in a different time zone).
F11 OPERATING MANUAL • A (< 2 sec) - to step forward through selections of OFF, ON, and SET (Fig. 7B). • M (< 2 sec) - to step back through the selections. • S (< 2 sec) - to save the selection. >> If OFF or ON is selected, operation reverts to the CDT Lead-in screen. >> If SET is selected, the Set CDT screen is displayed. • S (2 sec) - to revert to CDT Lead-in, if no setting change. • M (2 sec), or 2 minutes of no button action, will revert to Watch Main Time. Set CDT, information includes (Fig.
F11 OPERATING MANUAL SET TIME (& DATE) Sequence >> Lead-in >> Date Format >> Hour Format >> Dual Time >> Time of Day >> Date. set points remain as set until changed. Set Time Lead-in, information includes (Fig. 12): > Graphics Go To and SEt - t. • • • • S (< 2 sec) - to access Set Date Format. A (< 2 sec) - to step forward to Chrono Lead-in. M (< 2 sec) - to step back to Daily Alarm Lead-in. M (2 sec), or 2 minutes of no button action, will revert to Watch Main Time. Fig.
F11 OPERATING MANUAL • • • • • A (hold) - to scroll upward through Year set points (8/sec) from 2013 to 2055, in increments of 1. A (< 2 sec) - to step upward through Year set points. M (< 2 sec) - to step back through set points. S (< 2 sec) - to save the Year setting and flash the Month digits. S (2 sec) - to step back to Set Time of Day. • • • • • A (hold) - to scroll upward through Month set points (8/sec) from 1 to 12 in increments of 1. A (< 2 sec) - to step upward through set points.
F11 OPERATING MANUAL surface mode © 2002 Design, 2013 13 Doc. No.
F11 OPERATING MANUAL SURFACE MODE Surface Main is the default screen displayed while in FREE Mode. In addition to Surface Interval Time and Dive Number, a CDT (Countdown Timer) is displayed (unless it is set Off) which you can start, stop, and reset. Like Watch mode, you can access a sequence of selections including >> ALTs (additional data), Countdown Timer, Set Alarms, Set Utilities, Serial Number, and Chronograph. The CDT is separate from the one featured in Watch Mode.
F11 OPERATING MANUAL FREE CDT (COUNTDOWN TIMER) The FREE Mode CDT (which is not the same one as the Watch CDT) counts down time values in minutes:seconds. Unless it is set Off, it is displayed on the Surface Main and if a dive is started it will be displayed on the Dive Main. When set for Auto, the countdown will keep repeating after counting down to 0:00 until stopped by S (< 2 sec). CDT Lead-in, information includes (Fig. 24): > Graphics Go To and Cdt with icon. • • • • • • Fig.
F11 OPERATING MANUAL SURFACE SET MODES To access: SURF MAIN >> ALT 1 >> ALT 2 >> CDT >> SET ALARMS >> SET UTILITIES. • A (< 2 sec) to access and step through the sequence. > Set points can also be changed using the AERIS Computer Interface program. > Settings remain at the values saved until changed. SET ALARMS Sequence: Lead-in >> AUD >> SRT >> RTI >> RDI >> DA1 to DA6. • A (< 2 sec), while viewing CDT Lead-in, to access Set Alarms Lead-in.
F11 OPERATING MANUAL Set RTI (Repeating Time Interval) Alarm, information includes (Fig. 30): > Graphic RTI with min_sec icons. > Time (min:sec). > Graphic ON (or OFF), flashing. • A (< 2 sec) - to step forward through the selections of OFF, ON, and SET. • M (< 2 sec) - to step back through the selections. • S (2 sec) - to step back to Set SRT. • S (< 2 sec) - to save the setting. Fig. 30 - SET RTI ALARM > If OFF or ON is saved, operation will advance to Set RDI Alarm.
F11 OPERATING MANUAL Set DA1 Audible Alarm (DA2 to DA6 similar), information includes (Fig. 33): > Graphics DA1 and bEEP. > Number of beeps (1 to 10), flashing upon access. > Number of times the beeps are to repeat (1t to 3t, t = times). • A (< 2 sec) - to step upward through the Beep set points from 1 to 10 one at a time. • M (< 2 sec) - to step back through the Beep set points one at a time. • S (2 sec) - to step back to Depth digits flashing.
F11 OPERATING MANUAL Set Wet Activation, information includes (Fig. 36): > Graphics WET ACt. > Graphic ON (or OFF), flashing. • A or M (< 2 sec) - to toggle between ON and OFF. • S (2 sec) - to step back to Set Units. • S (< 2 sec) - to save the setting and access Set Water Type. Fig. 36 - SET WET ACTIVATION Set Water Type, information includes (Fig. 37): > Graphics H2O tYPE. > Graphic SEA (or FrSH), flashing. • A or M (< 2 sec) - to toggle between SEA and FrSH.
F11 OPERATING MANUAL SERIAL NUMBER (SN) • A (< 2 sec), while viewing Set Utilities Lead-in, - to access the Serial Number screen. Information includes (Fig. 43): > Graphic SN. > Factory programmed Serial Number (up to 6 digits). > Firmware (the unit's operating software) revision number (e.g., graphic r1A). • A (< 2 sec) - to step forward to Chrono Lead-in. • M (< 2 sec) - to step back to Set Utilities Lead-in • M (2 sec), or 2 minutes of no button action, will revert to SURF MAIN.
F11 OPERATING MANUAL DAY LOG LEAD-IN, information is to include (Fig. 45): > Graphics Go To dAY LOG with Log (book) icon. • A (2 sec) - to step forward to Full Log Lead-in. • M (2 sec) - to step back to Watch Main or SURF MAIN • A (< 2 sec) - to access Day Log Data 1. DAY LOG DATA 1, information is to include (Fig. 46): > Log (book) icon. > Graphic No and dive number (1 to 99) for that calendar day, or session of the day if reset. > Time of Day that the dive began (hr:min_sec) with AM (or PM) icon.
F11 OPERATING MANUAL FULL LOG LEAD-IN, information is to include (Fig. 50): > Graphics Go To FULL LOG with Log (book) icon. • A (2 sec) - to step forward to Day History Lead-in. • M (2 sec) - to step back to Day Log Lead-in • A (< 2 sec) - to access Full Log Data 1. Full Log Data screens and button operations are the same as those previously described for Day Log. Fig.
F11 OPERATING MANUAL FULL HISTORY LEAD-IN, information is to include (Fig. 56): > Graphics Go To, FULL, and HiST, solid. • A (2 sec) - to step forward to Watch or SURF Main. • A (< 2 sec) - to access Full History Data 1. FULL HISTORY DATA 1, information is to include (Fig. 57): > Graphic TOTL, indicating that the information displayed is for the total number of dives and total Dive Time recorded. > Total accumulated Dive Time (up to 9999) with graphic Hr, then starting over at 0001.
F11 OPERATING MANUAL DIVE MODE Dive Mode is activated upon descent to the DSD (Dive Start Depth) set for 1 second, then the dive ends upon ascent above 2 FT (0.6 M) for 1 second. If a descent is made while the Chrono is on the display, it will remain on the display (even after a dive is started), until M is pressed/released to display the Dive Main. © 2002 Design, 2013 24 Doc. No.
F11 OPERATING MANUAL DIVE MODE Prior to the first dive of a new series, if Wet Activation is set Off, Dive Mode will not activate during operation in any Watch Mode. It must to be in FREE Mode prior to activating Dive Mode. If Wet Activation is set On, Dive Mode will activate from any operating surface mode including Watch modes when it senses the DSD (Dive Start Depth) set for 5 seconds.
F11 OPERATING MANUAL WARNINGS & ALARMS © 2002 Design, 2013 26 Doc. No.
F11 OPERATING MANUAL ALARMS When the Audible sounds, the LED will flash. Also, the Backlight will come On (if Off) for 10 seconds, and a flashing icon or message will be displayed as an indication that an event is occurring and as a reminder to view the display to identify the event. When the Audible stops, the LED will extinguish and the message will clear. If the Audible is set OFF, it will not sound and the LED will not flash for any cautionary situation.
F11 OPERATING MANUAL REFERENCE © 2002 Design, 2013 28 Doc. No.
F11 OPERATING MANUAL UPLOADING SETTINGS AND DOWNLOADING DATA The F11 is configured with a Data Port located on the right side that enables it to be connected to a PC or Mac through a USB port using the AERIS Computer Interface cable, when viewing the Watch Main Time screen. The Settings Upload portion of the Computer Interface program can be used to set/change the Main Time/Date selections, Set Alarms, and Set Utilities.
F11 OPERATING MANUAL WARNINGS: Never, under any circumstances, poke any object through any slots or holes of the module. Doing so may damage the depth sensor, possibly resulting in erroneous depth displays. If you are in doubt about the accuracy of your unit's depth readings, DO NOT attempt to dive with it until it has been inspected by AERIS. Never pressure test the module in an air environment. Doing so may damage the depth sensor, possibly resulting in erroneous depth or time readings.
F11 OPERATING MANUAL Battery Removal • There is no need to remove the straps. • Remove the (4) retaining screws located on the back of the case (Fig. 79) by turning them counter clockwise with a small flat tip 3mm screw driver. • Carefully separate the front and back sections. If necessary, insert a small flat tip screw driver in the slot machined into the cover at the 11 o'clock position (Fig. 80a) and gently pry the cover loose, then lift it off the case (Fig. 81).
F11 OPERATING MANUAL SPECIFICATIONS CAN BE USED AS • Watch • Digital Gauge for Free Dive activity WATCH MODES • Main Time • Alternate (supplemental information) • Countdown Timer • Daily Alarm • Set Time/Date • Chronograph (run timer) • Set Time/Date: Date Format (M.D, D.M) Hour Format (12, 24) Dual Time Differential (OFF, +1 to +23, - 1 to - 23 hours) Time of Day (hr:min) Date (Year, Month, Day) Factory Settings: M.
F11 OPERATING MANUAL SPECIFICATIONS (continued) OPERATIONAL PERFORMANCE Function: • Depth • Timers Accuracy: ±1% of full scale 1 second per day Dive Counter: • Dives 1 to 99, 0 if no dive made yet. • Resets to Dive 1, after midnight or by A+S (2 sec). Dive Log Modes: • Stores 99 most recent dives in memory for viewing. • After 99 dives, adds next dive in memory and deletes the oldest dive. Altitude: • Operational from Sea Level (= 0 to 3,000 feet/915 meters) to 14,000 feet (4,270 meters) elevation.
F11 OPERATING MANUAL GLOSSARY Audible Alarm ‑ A emitted tone that alerts the diver to potential danger. Depth Sensor ‑ An electro-mechanical device that converts water pressure into an electrical signal, that is converted to a visual depth display. Display ‑ A visual readout of information. Dive Log Mode ‑ A display of recorded dive information. Elapsed Dive Time ‑ The total time spent underwater during a dive that begins at the start depth set and ends upon ascent to the end depth.
F11 OPERATING MANUAL INSPECTION / SERVICE Record F11 Serial Number: ___________________________________________________________________________________________________ F11 Firmware Rev: ___________________________________________________________________________________________________ Date of Purchase: ___________________________________________________________________________________________________ Purchased from: ____________________________________________________________________________________
F11 OPERATING MANUAL F11 OPERATING MANUAL © 2002 Design, 2013 36 Doc. No.