Operating Instructions and Installation Instructions

39
English
IFCW3LJ 1210 - 5375700_01
The programme requires the system to circulate chilled water.
1) PRESS THE ON/OFF
OR KEYS
The fan coil unit comes on. The fan coil unit automatically starts in cooling mode.
2) PRESS THE MODE KEY
Press the MODE key repeatedly until the word COOL appears on the display
(TLW2) or the LEDs on wired control panel (PFW2) turns on COOL.
3) PRESS THE KEYS
OR TO CONTROL THE TEMPERATURE
The key with the symbol
allows increases of 1°C
The key with the symbol
allows decreases of 1°C
The display shows the set point value between 16 and 30 °C.
4) PRESS THE FAN KEY
OR
When the FAN key is pressed repeatedly, the system can move to the minimum
speed (LOW), medium speed (MED) and high speed (HIGH) or to the (AUTO)
speed controlled by the microprocessor.
5) TO DIRECT THE AIR FLOW
To ensure optimum air distribution, adjust the horizontal blades and the vertical
blades in such a way that the air flow does not hit people directly. The vertical air
flow blades must be set manually before starting up the motorised blades.
Never adjust the motorised horizontal blades manually.
When the LOUVER key is pressed repeatedly, the horizontal blade is adjusted to 4
fixed blade positions, then a swinging blade movement will begin. If you wish to
stop the blade in a particular position, press the LOUVER key.
When the SWING key is pressed a swinging blade movement will begin. If you
wish to stop the blade in a particular position, press the SWING key again.
6) PRESS THE SEND KEY (TLW2)
To transmit the new parameters shown on the LCD to the main control unit.
6
PFW2
TLW2
1) PRESS THE ON/OFF OR KEYS
The fan coil comes on and the display is switched on.
2) PRESS THE MODE KEY
Press the MODE key repeatedly until the word FUN appears on the display
(TLW2) or the LEDs on wired control panel (PFW2) turns on FUN.
3) PRESS THE FAN
OR KEYS
When the FAN key is pressed repeatedly, the system can move to the minimum
speed (LOW), medium speed (MED) and high speed (HIGH) or to the (AUTO)
speed controlled by the microprocessor.
4) TO DIRECT THE AIR FLOW
To ensure optimum air distribution, adjust the horizontal blades and the vertical
blades in such a way that the air flow does not hit people directly. The vertical air
flow blades must be set manually before starting up the motorised blades.
Never adjust the motorised horizontal blades manually.
When the LOUVER key is pressed repeatedly, the horizontal blade is adjusted to 4
fixed blade positions, then a swinging blade movement will begin. If you wish to
stop the blade in a particular position, press the LOUVER key.
When the SWING key is pressed a swinging blade movement will begin. If you
wish to stop the blade in a particular position, press the SWING key again.
5) PRESS THE SEND KEY (TLW2)
To transmit the new parameters shown on the LCD to the main control unit.
OPERATING IN JUST VENTILATION MODE
This programme is used to move the room air and avoid stagnation. The ventila-
tion programme is particularly indicated as a support to heating systems without
fans, as when a stove is used to heat the room. All the hot air gathers by the ceil-
ing. When the unit is set in ventilation mode, the hot air is distributed uniformly
throughout the room.
PFW2
TLW2
COOLING PROGRAMME (COOL)
FAN PROGRAMME (FAN)