Instructions / Assembly

H
H
R
F
L
N
G
HEAT 1
HEAT 2
LIGHT
EXHAUST
HOT
NEUTRAL
GROUND
HEAT 1
HEAT 2
LIGHT
HOT BLACK
HOT BLACK
NEUTRAL WHITE
GROUND GREEN
BACK OF SWITCH
BREAKER
STOP: READ BEFORE INSTALLATION
716 MODEL
This unit MUST be installed by a licensed Electrician.
The power source MUST come from the BREAKER to the UNIT and then to the SWITCH.
Thermal sensors must be live in order for fan to come on and off automatically. Failure to do this will result in damage to the unit and void
all warranty.
* 15 AMP breaker required.
* 14 gauge wire is sufficient.
* Unit CANNOT be mounted
in a shower