Specification Sheet

A716R SERIES
4 Bulb Heater with Ventilation and Light
Description:
Ventilating fan shall be low noise,
ceiling mount engineered for continu-
ous operation. Suitable for new
construction or remodeling. Con-
forms to UL/CUL safety standards
with GFCI wiring. Includes 4 anti-
blast infrared heat lamps and 60W
incandescent bulb. 4 function wall
switch included.
Motor/Blower:
Permanently lubricated enclosed
condenser motor.
Engineered for continuous
operation.
Power rating shall be 120v/60Hz.
Fan shall be UL and cUL listed
when GFCI protected.
Motor equipped with thermal
shut-off. Requires 15 amp circuit.
Housing:
Rust proof painted Steel Body
4” Duct connector
Built-in damper
Articulating and expandable
anti-vibration brackets included.
Designed for installation in
ceilings with a minimum of 8”
clearance.
Grille:
Low maintenance, attaches to housing
with torsion springs.
Finishes: White (W), Satin Nickel
(SN), Satin Gold (SG), Oil Rubbed
Bronze (OR), Farmhouse Black (FHB).
Ventilating Area:
For bathrooms up to 100 square feet.
Warranty:
6 Years when installed by licensed
professional.
Architectural Specifications:
Exhaust fan will be ceiling mount with
no less than 100CFM and no more
than 1.2 Sones at 0.1 static pressure
in inches water gauge. Power con-
sumption shall be no greater than
1160 watts. The motor will be perma-
nently lubricated, engineered for con-
tinuous operation. Duct diameter will
be 4” round. Exhaust fan, heater and
light may be wired separately. Fan
will not be installed directly over tub/
shower enclosure. When used with
GFCI branch circuit wiring shall be
UL/CUL listed for use in insulated
ceilings (Type I.C.).