Dimensions Guide

Model: ABF 110DH L5 Series
4” Duct
Static Pressure (inches w.g.)
0.1
0.25
Air Volume (CFM)
112
93.9
Noise (sones)
0.9
1.2
Power Consumption (Watts)
15.2
16.7
Energy Efficiency (CFM/Watts)
7.4
5.6
Speed (RPM)
1095
N/A
ENERGY STAR rated
Yes
Grille Dimensions
13” x 13”
Model
Qty
Project
Location
Architect
Engineer
Contractor
Submitted by
Specifications
ABF 110DH L6 Series
Quiet Adjustable Speed Bathroom Fan with
Humidity Sensor and LED Light/Night Light
ETL/cETL Listed for installation over tub/shower enclosure
when used with GFCI circuit wiring
Description: Quiet DC (Direct Current) bathroom fan with adjustable
speed control (50-80-110 CFM) engineered for continuous run User
adjustable Humidity Sensor 10W 3000K 850 Lumens dimmable LED
light and 0.7W night light Ceiling mount Suitable for new
construction or remodeling HVI certified ENERGY STAR certified
ETL/cETL listed for use in insulated ceilings (Type I.C.).
Motor/Blower: Brushless high performance DC motor engineered for
continuous energy efficient operation; power rating 120v/60Hz; motor
equipped with thermal shut off.
Housing: Galvanized steel body; duct connector adapts to 4”, 5” or 6”,
built-in back draft dampener; patented quick mounting anti-vibration
bracket included; designed for installation in ceilings with minimum of
8” clearance.
Grille: Low maintenance, wipe clean; attaches to housing with torsion
springs.
Finishes: White (W); Satin Nickel (SN); Oil Rubbed Bronze (OR).
Light: Energy efficient dimmable 10W LED with 0.7W night light
Ventilating Area: For bathrooms up to 110 sq ft.
Installation: Must be installed by licensed professional. Complete
installation instructions included.
Warranty: 6 Years
Architect’s Specifications: Ventilation fan will be ceiling mount,
ENERGY STAR qualified, adjustable speed of 50-80-110 CFM with no
less than 110 CFM and no more than 1.0 Sones as certified by HVI at
0.1 static pressure in inches water gauge. Power consumption shall be no
greater than 15.2 watts and ENERGY STAR rated with an efficiency
rating of no less than 7.4 CFM/watt. Light shall be 10W 3000K
dimmable LED and include one 0.7W LED night light. The motor will
be enclosed brushes DC motor engineered for continuous operation.
CFM switch tab will allow for 3 separate airflow (CFM) settings for 4”,
5”, or 6” duct. Fan will begin operation when humidity rises above user
adjusted setpoint. Adjustable timer. Fan shall be listed for tub/shower
enclosure when used with GFCI branch circuit wiring and shall be
ETL/cETL listed for use in insulated ceiling (Type I.C.). Fan shall be
ASHRAE 62.2, LEED, California Title 24/JA8, and Washington VIAQ
compliant.
L6 (OR) L6 (SN) L6 (W) Grille