How to Guide

Aero Pure Wiring Diagrams DH G & L Series
BATH FAN
ADDITIONAL WIRING DIAGRAMS
Model No.
ABF110DHG5 Series
ABF110DHG6 Series
ABF110DHL1 Series
ABF110DHL5 Series
ABF110DHL6 Series
ABF110DCMH-S G5
ABF110DCMH-S G6
ABF110DH G5, ABF110DH G6, ABF110DCMH-S G5, ABF110DCMH-S G6
(2 Switches required)
- Be sure to turn OFF the power at the breaker before installing to avoid electrical shock or injury.
- The primary switch is what is bringing power into the unit. See DIAGRAM A for switch requirement.
-The secondary switch is the On/Off switch that is connected to the wires marked Red/Signal on
DIAGRAM A.
- Be sure that the secondary switch is a traditional On/Off switch and does not contain a Neutral hookup.
A Ground (Green wire) is fine. Typically, there will be two brass screws on one side and a green screw on
the other side of the switch. See DIAGRAM A for more information.
- Make sure both the primary switch (the switch that feeds power into the unit directly) and the secondary
switch (Red/Signal wires) are in the OFF position while you are wiring the unit.
- Once the unit, and both switches are properly wired, per the instructions and diagrams provided, turn
the power ON at the breaker, then turn ON the primary switch (the switch feeding power into the fan) and
leave the secondary switch OFF (the switch connected to the red wires coming out of the unit). Be sure to
turn the Low Airflow knob located at the back of the unit to 0 before turning on the primary switch.
- With the grille cover removed from the fan, place a small cup of hot steaming water underneath the fan
humidity sensor that is located to the left of the motor. The humidity sensor has a USB plug attached to it.
Be sure the USB is plugged in.
- With the primary switch on, and the secondary switch off, the hot steaming water underneath the
humidity sensor will turn the fan on.
- If the fan does not turn on, rotate the Low Airflow knob from 0 to 100 and back again to 0 to reset the
unit. Also, rotate the humidity knob, located on the sensor to 60 or in the middle of the 30 and 80 markers
FAN WITH HUMIDITY SENSOR ONLY

Summary of content (3 pages)