Use and Care Manual

P/N: 102368
REV F
Figure 4
Figure 5
Figure 6
Figure 7
Figure 9
Figure 10
9.) Expose and clean a 32” x 32” square area on the top of the septic tank centered on the clean-
out opening on the tank.
10.) With the white tape upward, apply the butyl sealant rope around the groove on the bottom of
the adapter flange (Figure 3A), overlapping and kneading the ends of the butyl rope together
(Fig. 8).
11.) Remove the white tape from the sealant rope and discard the tape.
12.) Center the riser assembly on the tank clean-out opening and apply pressure around the
perimeter of the base flange above the butyl sealant rope to compress sealant between the
tank and the adapter flange.
13.) Drill (4) 5/32” diameter holes through the four corners of the adapter flange (Fig. 9) at least 1
3/4” deep into the tank cover. If the tank in made of concrete, use a carbide tip masonry bit.
14.) Fasten the base plate to the tank using four (4) enclosed blue screws.
15.) Backfill around riser with sand or washed stone to prevent movement from frost if applicable in
your climate.
16.) Always re-install (4) cover security screws and tighten with
appropriate driver tool to secure Riser Cover to Riser Pipe (Fig.10) & (Fig. 11)
WARNING: FAILURE TO PROPERLY SECURE THE RISER COVER WILL
CREATE A SERIOUS SAFETY RISK!
Figure 11
6
Mounting
Slot
(4) Cover Screws
into (4) pre-drilled
holes
Figure 8
(4) Mounting Holes
Butyl Rope in Bottom
Groove All Around
Screw through
Hole in Pouch
Always Return Guide to Pouch after
Installation or Servicing!
(4) pre-drilled holes
for cover screws
.