User Manual

50289-BDA
USE OR DISCLOSURE OF DATA CONTAINED ON THIS PAGE IS SUBJECT TO THE
RESTRICTION ON THE TITLE PAGE OF THIS MANUAL
4
800MHz BDA
Model 50289-BDA
Specifications Continue:
DC Power Supply:
No. per enclosure: High Band: 3 (1 Dual Chassis/ 1 Single)
Low Band: 2 (1 Dual Chassis)
Input: 105-125 VAC, 50-400Hz, single phase
Output (each supply): 12 VDC+/- 0.5V @20 amps
Operating Temperature:
-20°C to +70°C
Battery Charger:
Type: Multi-Stage (Bulk/Absorption/Float)
DC Output: 13.8-14.8Vdc (depending on setting)
AC Input: 95-125 VAC
Charging Rate: Bulk Charge: 40 amps max.
Absorption: 5 amps max.
Float: 0.05 amps
Battery:
Optionally Provided or User Supplied
Specifications dependant on required UPS cycle
System Load: 95 amp/hr
Software:
Title: 800MHz-Linc (50486-09-01)
Version: 1.0
Operator, User Functions: Time-out Timer (set time interval)
Mode (Keyed or Continuous)
Technician Functions: Set Attenuation
Set Frequency
Set RSSI Attack
Peripheral Requirements:
Optionally provided or User supplied:
Operating System (requirements): Window 95, Windows 98, or Windows NT 4.0
(or higher)
Computer or Laptop (requirements): 486DX66Mhz (minimum)
Communication, Serial Port (requirements): 4800 baud,
N8+1 (8 bits, no parity)