Installation manual

Model 8210A-2-5 IM-377
Aeroflex / Weinschel
14
5-4. RS-422/RS485 OPERATION: The RS422/RS485 Serial mode is useful in applications requiring long cable
lengths (up to5000 ft at 9600 baud), or in electrically noisy environments. All communication parameters available for
the RS232 port are available under RS422 operation (baud rate, handshaking, etc). Full Duplex operation is
supported. The RS422 port utilizes a 9-pin connector. The pin-out for the connector is show below. For clarity, the
signal names and directions are relative to the8210A-2-5. The signals are electrically compatible with either RS-422 or
RS485.
Pin
Signal Name Description Direction
1 RxD+ Receive data input
2 RxD- Receive data input
3 TxD+ Transmit data output
4 TxD- Transmit data output
5 GND Ground ---
6 CTS+ Clear to Send input
7 RTS- Request to Send output
8 CTS- Clear to Send input
9 RTS+ Request to Send output
1
2
3
4
5
9
8
7
6
RXD+
RXD-
TXD-
TXD+
GND
RTS+
CTS -
RTS -
CTS+
RS422
9-pin DB9 Pinout