IM-493 IM-493 Model 8310-XX-X-XN Operation & Installation Manual Model 8310 SmartStep Programmable Attenuator Units w/Ethernet ® This documentation may not be reproduced in any form, for any purpose unless authorized in writing by Aeroflex / Weinschel, Inc. © Aeroflex / Weinschel, Inc. Frederick, Maryland 2008-2011 Aeroflex / Weinschel Manual Rev.
SAFETY SUMMARY SAFETY SUMMARY • To minimize shock hazard, the instrument chassis DEFINITIONS. The following definitions apply to WARNINGS, CAUTIONS, and NOTES found throughout this manual. WARNING must be connected to an electrical ground. Using the supplied three-conductor power cable ensures that the instrument can be firmly connected to the ac power source and electrical ground at a grounded power outlet. If using a 3-2 wire adapter be sure to connect the ground lead to earth ground.
SAFETY SUMMARY NOTE CAUTION • All procedures and/or steps identified as must be followed exactly as written and according to industry accepted ESDS device handling procedures. Failure to comply WILL RESULT in ESDS damage. • DO NOT use a nylon bristle brush in the solvent as the bristles may dissolve and cause damage to the circuit card or component. DO NOT return any instrument or component to Weinschel Corporation without receiving prior factory authorization. SAFETY SYMBOLS.
Model 8310-XX-X-XN IM-493 TABLE OF CONTENTS 1. GENERAL INFORMATION ......................................................................................................................................... 5 1-1. PURPOSE .....................................................................................................................................................................5 1-2. SCOPE ................................................................................................................
Model 8310-XX-X-XN IM-493 5-4.3. OUTPUT DATA FORMAT ...............................................................................................................................26 5-4.4. NOTATIONAL CONVENTION .........................................................................................................................26 5-5. COMMON COMMANDS ..................................................................................................................................... 27-28 5-6.
Model 8310-XX-X-XN IM-493 MODEL 8310-38-3-TN ATTENUATOR UNIT ASSEMBLY REPLACEABLE PARTS LIST (P/N 193-7038-11) ...................47 MODEL 8310-38-4-TN, ATTENUATOR UNIT ASSEMBLY REPLACEABLE PARTS LIST (P/N 193-7038-12) ..................47 MODEL 8310-38-F / R-EN, ATTENUATOR UNIT ASSEMBLY REPLACEABLE PARTS LIST (P/N 193-7038-13) ............48 MODEL 8310-38-2-F / R -EN, ATTENUATOR UNIT ASSEMBLY REPLACEABLE PARTS LIST (P/N 193-7038-14) ........
Model 8310-XX-X-XN IM-493 9. GENERAL INFORMATION: 1-1 PURPOSE: This manual contains setup and operation information for the Aeroflex / Weinschel’s 8310-XXX-XN Series of Programmable Attenuator Units with Ethernet Control. The manual also provides component location, reference designators, part numbers, and nomenclature to identify all the assemblies and sub-assemblies of the Attenuator Unit.
Model 8310-XX-X-XN IM-493 1-5. UNPACKING AND INSPECTION: Upon unpacking the equipment, retain the shipping container and packing material for future shipment for recalibration. Perform the following initial inspection: a. Carefully look at the outside of the shipping container for discoloration, stains, charring, or other signs of exposure to excessive heat, moisture, or liquid chemicals.
Model 8310-XX-X-XN IM-493 1-8. RELATED MANUALS: The following manuals contain information that may be used in conjunction with this manual to operate, service, or calibrate this instrument. Title Manual H4-1 and H4-2 Federal Supply Code for Manufacturers Cataloging Handbook 1-9. ELECTROSTATIC DISCHARGE SENSITIVE: The equipment documented in this manual contains certain Electrostatic Discharge Sensitive (ESDS) components or parts.
Model 8310-XX-X-XN IM-493 2. SPECIFICATIONS: 2-1. GENERAL SPECIFICATIONS: Input Power Requirements ac 115 to 230 Vac, 1.
Model 8310-XX-X-XN IM-493 2-2. CONFIGURATIONS\RF SPECIFICATIONS: Table 1. 3200T & 150T Series-Mechanical Relay: Model No Attenuator Value Frequency Range (GHz) Insertion Loss SWR No of Channels Attenuator Type Connector Type Connector Location Drawing No 8310-1-FN 63/1 dc-1.0 (75 ) 6.0 dB max 1.6 max 1 3250T-63 BNC/F Front 193-7001-4 8310-1-RN 63/1 dc-1.0 (75 ) 6.0 dB max 1.6 max 1 3250T-63 BNC/F Rear 193-7001-4 8310-1-2-FN 63/1 dc-1.0 (75 ) 6.0 dB max 1.
Model 8310-XX-X-XN IM-493 Table 1. 3200T & 150T Series-Mechanical Relay (Continued): Model No Attenuator Value Frequency Range (GHz) Insertion Loss SWR No. of Channels Attenuator Type Connector Type Connector Location Front 8310-201-FN 70/10 dc-18 3.25 dB max 1.75 1 150T-70 Sma/F 8310-201-RN 70/10 dc-18 3.25 dB max 1.75 1 150T-70 Sma/F Rear 8310-201-2-FN 70/10 dc-18 3.25 dB max 1.75 2 150T-70 Sma/F Front 8310-201-2-RN 70/10 dc-18 3.25 dB max 1.
Model 8310-XX-X-XN IM-493 3. INSTALLATION: 3-1. RACKMOUNTING: Standard 8310 Attenuator Units are shipped with four plastic feet mounted to the bottom cover, this allows the user to place the instrument on any bench or to stack the with other Weinschel instruments. The Model 8310 can also be rack mounted as a single unit using Rack Mounting Kit (P/N 193-8033-1) or two Model 8310’s can be mounted together using Rack Mounting Kit (P/N 193-8033-2).
Model 8310-XX-X-XN IM-493 The AC Power Connector, located on the left side of XF1 (Figure 2), is a plug-type, prong insert connector with three conductors for connection of the power cord (P/N 068-21) to the Power Supply Assembly located within the HotSwitching High Power Attenuator Unit. This connector also grounds the chassis of the Hot-Switching High Power Attenuator Unit when the ac power cord is connected to a grounded wall outlet.
Model 8310-XX-X-XN IM-493 4. FRONT PANEL CONTROLS & INDICATORS: The following paragraphs provide setup and general guidelines for operating the Model 8310-XXX-XN Programmable Attenuator Unit and its different bus configurations. Figure 3. 8310-XXX-XN Series Front Panel ENTRY keys: The numeric entry keys allow the user to directly enter numeric values. When using the keypad, values are not updated until the ENT (enter) key is pressed.
Model 8310-XX-X-XN IM-493 5. REMOTE OPERATION: The following paragraphs provide setup and general guidelines for operating the Model 8310 using an external controller. 5-1. COMMUNICATIONS INTERFACE: The unit provides for control via a number of interface methods, including IEEE 488.2, RS232 serial, and 10/100 baseT Ethernet. Interface functions are split between two assemblies: 1). The main controller (generically referred to as the 8210A), 2). The exadeci control interface.
Model 8310-XX-X-XN IM-493 Ethernet Mode: This position internally connects the serial port of the device server to the serial port of the 8210A, allowing for network control of the unit. In this mode, the external serial port is non-functional. The serial communication settings of the device server must be set to match that of the 8210A for proper operation. Console Mode: This position connects the RS232 port directly to the XPort device server.
Model 8310-XX-X-XN IM-493 Assigning an IP Address in DeviceInstaller a. Click Start->Programs->Lantronix->DeviceInstaller->DeviceInstaller. If your PC has more than one network adapter, a message displays. Select an adapter and click OK. b. Click the Search icon and select the unit from the list of Lantronix device servers on the local network. c. Click the Assign IP icon. d. If prompted, enter the hardware address (on the product label) and click Next. e.
Model 8310-XX-X-XN IM-493 5-1.3.3 ARP and Telnet: If a serial port is unavailable, you can use the Address Resolution Protocol (ARP) method from UNIX and Windows-based systems to assign a temporary IP address. To assign a temporary IP address: a. On a UNIX or Windows-based host, create an entry in the host's ARP table using the intended IP address and the hardware MAC address of the Xport, which should be available on the rear-panel of the unit.
Model 8310-XX-X-XN IM-493 AutoIP does not replace DHCP. The unit continues to look for a DHCP server on the network. If it finds a DHCP server, the unit switches to the DHCP server-provided address and reboots. NOTE If a DHCP server is found, but it denies the request for an IP address, the unit does not attach to the network, but waits and retries. AutoIP can be disabled by setting the unit’s IP address to 0.0.1.0. This setting enables DHCP but disables AutoIP. 5-1.3.
Model 8310-XX-X-XN IM-493 e. Pressing the 'Enter' key should display the SETUP mode settings: NOTE There is a timeout function built into the SETUP mode. If you do not press the 'Enter' key within 2-3 seconds of the signon message appearing, you will need to turn off the power and start again. If the timeout occurs, you will see the characters “?!?” displayed on the screen. *** basic parameters Hardware: Ethernet TPI IP addr - 0.0.0.
Model 8310-XX-X-XN IM-493 - Trigger 1 Serial trigger input: disabled Channel: 1 Match: 00,00 Trigger input1: X Trigger input2: X Trigger input3: X Message : Priority: L Min. notification interval: 1 s Re-notification interval : 0 s - Trigger 2 Serial trigger input: disabled Channel: 1 Match: 00,00 Trigger input1: X Trigger input2: X Trigger input3: X Message : Priority: L Min.
Model 8310-XX-X-XN IM-493 Change Setup: 0 Server 1 Channel 1 3 E-mail 5 Expert 6 Security 7 Defaults 8 Exit without save 9 Save and exit Your choice ? Parameters stored ... Turn off power. To verify the settings you can use the Xport Monitor Mode. To enter Monitor mode, hold down the 'z' key while powering up the unit. After a few seconds, you should see *** NodeSet 2.
Model 8310-XX-X-XN IM-493 You should now be able to communicate with the device. To send commands, you can use the Windows Telnet application to open a connection to Port 10001 (the default serial device tunnel port) C:\WINDOWS>telnet 10.100.103.49 10001 Characters that you type in the telnet window will be sent to the device. For example, typing “*IDN?” Should get a response similar to: Weinschel, 8310, 001, V2.
Model 8310-XX-X-XN IM-493 5-2.1. RS-232 Operation: The RS-232 Serial port is a 9-pin connector that is compatible with the pin-out of the serial port on a PC. It allows the use of a null-modem style cable. The pin-out for the connector is show below. For clarity, the signal names and directions are relative to the 6631.
Model 8310-XX-X-XN IM-493 5-3 Status Reporting The 6853 implements the 488.2 Status Reporting Structure, which utilizes the IEEE488.1 status byte with additional data structures and rules. The Status Byte Register can be read with either a serial poll (IEEE-488 operation only) or the *STB? Common query command. The Service Request Enable Register (SRE) allows the user to select which bits in the Status Byte Register may cause service requests.
Model 8310-XX-X-XN IM-493 The Status Reporting Registers may be used for serial communications, with certain limitations. The Status Byte Register can only be read via the *STB? Query command, as the exad port does not provide for a serial poll operation. Also, as data in the Output Queue is sent automatically during serial operation, the MAV message available bit in the STB serves no purpose. 5-4.
Model 8310-XX-X-XN IM-493 Real Numeric Program Data-This data type includes decimal numbers containing a sign, decimal point, and/or an exponent. The format is as follows: [sign]digits[.[digits][E[sign]digits]] 2 2.5 -35.
Model 8310-XX-X-XN IM-493 5-5. COMMON COMMANDS *CLS Function: Syntax: Argument(s): Remarks: Return Value: Example(s): Clears the Status Byte and Event Status Registers. *CLS none This function is used to clear the Status Byte and the Event Status Registers. none *CLS *ESE Function: Syntax: Argument(s): Remarks: Return Value: Example(s): Sets the Event Status Enable Register. *ESE mask mask integer bitmask This function is used to set the Event Status Enable Register to the value specified by mask.
Model 8310-XX-X-XN IM-493 *RST Function: Syntax: Argument(s): Remarks: Return Value: Example(s): Performs a device reset. *RST none This function is used to reset the device. none *RST *OPC Function: Syntax: Argument(s): Remarks: Operation complete service request. *OPC none This function generates the Operation Complete message (OPC) in the Standard Event Status Register when all pending device operations have finished.
Model 8310-XX-X-XN IM-493 5-6. GENERAL COMMANDS: CHAN Function: Syntax: Argument(s): Remarks: Return Value: Example(s): Selects the currently active channel CHAN chnum chnum integer channel number This function is used to select the currently active channel. none CHAN 1 CHAN? Function: Syntax: Argument(s): Remarks: Return Value: Example(s): Reads the current channel number CHAN? none This function is used to read the currently active channel number.
Model 8310-XX-X-XN RELATTN Function: Syntax: Argument(s): Remarks: Return Value: Example(s): IM-493 Sets attenuation relative to the reference setting RELATTN atten atten real desired value, in dB This function sets the attenuation of the currently selected channel to atten, relative to the reference value set when the REL command was executed.
Model 8310-XX-X-XN IM-493 6. MAINTENANCE: The following paragraphs provide general inspection and maintenance guide-lines for the Model 8310-XXXXN Attenuator Unit. 6-1. INSPECTION: Perform a visual inspection in conjunction with the maintenance activities schedule when a malfunction is suspected, or whenever an assembly is removed or replaced. 6-2.
Model 8310-XX-X-XN IM-493 6-3.3 MACHINED SURFACES AND HARDWARE: To remove light dirt and dust from mechanical parts such as castings, covers and other hardware proceed as follows: WARNING Compressed air used for cleaning and/or drying can create airborne particles that may enter the eye. Goggles/ face-shields should be worn. DO NOT direct air stream towards self or other personnel. Pressure should be restricted to a maximum 15 psi to avoid personal injury.
Model 8310-XX-X-XN IM-493 6-4. LINE VOLTAGE FUSE REPLACEMENT: The following steps provide procedures to replace the line voltage Fuse Assembly. This unit accepts a F1.5A, 250 Vac fuse for 115 Vac. WARNING Sufficient power levels are present at the Power Input Assembly to cause personal injury. Ensure that the instrument power cord is DISCONNECTED before attempting to change fuses.
Model 8310-XX-X-XN IM-493 7. REPLACEABLE PARTS LIST: This section lists and describes the parts located in the Model 8310-XXX-XN Programmable Attenuator Unit (P/N 193-9000-206). The Replaceable Parts Lists (RPL) is intended for use in identifying, locating, and requisitioning assemblies and components for the Model 8310-XXX-XN. 7-1 UNDERSTANDING REFERENCE DESIGNATORS: All assemblies and electrical parts are identified by standard reference designators (resistors R1, for example).
Model 8310-XX-X-XN IM-493 Model 8310-1-FN / -RN, Attenuator Unit Assembly Replaceable Parts List (P/N 193-7001-4, Rev. A): Find No.
Model 8310-XX-X-XN IM-493 Model 8310-1-3-TN Attenuator Unit Assembly Replaceable Parts List (P/N 193-7001-6, Rev. A): Find No.
Model 8310-XX-X-XN IM-493 Model 8310-2-FN / -RN, Attenuator Unit Assembly Replaceable Parts List (P/N 193-7002-3, Rev. A): Find No.
Model 8310-XX-X-XN IM-493 Model 8310-35-FN / -RN Attenuator Unit Assembly Replaceable Parts List (P/N 193-7035-9, Rev. A): Find No. Part Number 1 2 3 4 5 6 193-8034-3 193-8039 3200T-1 7004A-1 7005A-3 068-32-4/0 7 068-32-12/0 8 193-8041 11 12 13 090-301 074-761-1 074-921 14 15 18 MS24693-C3 NAS1635-04LR4 193-8135 19 20 089-4051 IM493 Description ASSY, BASE UNIT W /ETHERNET (+15V) MOUNTING PLATE ATTEN PRGM SMARTSTEP PLANAR BULKHEAD, 2.
Model 8310-XX-X-XN IM-493 Model 8310-35-3-TN Attenuator Unit Assembly Replaceable Parts List (P/N 193-7035-11, Rev. A): Find No. Part Number 1 2 3 4 5 6 193-8034-3 193-8039 3200T-1 7004A-1 7005A-3 068-32-4/0 8 193-8041 11 12 090-301 074-761-1 13 074-921 14 15 18 MS24693-C3 NAS1635-04LR4 193-8135 19 20 089-4051 IM493 Description ASSY, BASE UNIT W /ETHERNET (+15V) MOUNTING PLATE ATTEN PRGM SMARTSTEP PLANAR BULKHEAD, 2.
Model 8310-XX-X-XN IM-493 Model 8310-35-F / R-EN, Attenuator Unit Assembly Replaceable Parts List (P/N 193-7035-13, Rev. A): Find No. Part Number 1 2 3 4 5 6 193-8034-3 193-8039 3200T-1E 7004A-1 7005A-3 068-32-4/0 7 068-32-12/0 8 193-8041 11 12 13 090-301 074-761-1 074-921 14 15 18 MS24693-C3 NAS1635-04LR4 193-8135 19 20 089-4051 IM493 Description ASSY, BASE UNIT W /ETHERNET (+15V) MOUNTING PLATE ATTEN PRGM SMARTSTEP PLANAR BULKHEAD, 2.
Model 8310-XX-X-XN IM-493 MODEL 8310-35-3-T-EN, ATTENUATOR UNIT ASSEMBLY REPLACEABLE PARTS LIST (P/N 193-7035-15, REV. A): Find No. Part Number 1 2 3 4 5 6 193-8034-3 193-8039 3200T-1E 7004A-1 7005A-3 068-32-4/0 8 193-8041 11 12 13 090-301 074-761-1 074-921 14 15 18 MS24693-C3 NAS1635-04LR4 193-8135 19 20 089-4051 IM493 Description ASSY, BASE UNIT W /ETHERNET (+15V) MOUNTING PLATE ATTEN PRGM SMARTSTEP PLANAR BULKHEAD, 2.
Model 8310-XX-X-XN IM-493 Model 8310-36-FN / -RN Attenuator Unit Assembly Replaceable Parts List (P/N 193-7036-8): Find No. Part Number 1 2 3 4 5 6 193-8034-3 193-8039 3209T-1 7004A-1 7005A-3 068-32-4/0 7 068-32-12/0 8 11 12 13 193-8044 090-301 074-761-1 074-921 14 15 MS24693-C3 NAS1635-04LR4 18 193-8135 19 20 089-4051 IM493 Description ASSY, BASE UNIT W /ETHERNET (+15V) MOUNTING PLATE ATTEN PRGM, SMARTSTEP PLANAR BULKHEAD, 2.
Model 8310-XX-X-XN IM-493 Model 8310-36-3-TN Attenuator Unit Assembly Replaceable Parts List (P/N 193-7038-10, Rev. A): Find No. Part Number 1 2 3 4 5 6 193-8034-3 193-8039 3209T-1 7004A-1 7005A-3 068-32-4/0 8 193-8044 11 12 13 Description 090-301 074-761-1 074-921 ASSY, BASE UNIT W/ETHERNET (+15V) MOUNTING PLATE ATTEN PRGM, SMARTSTEP PLANAR BULKHEAD, 2.
Model 8310-XX-X-XN IM-493 Model 8310-36-F-EN / -R-EN Attenuator Unit Assembly Replaceable Parts List (P/N 193-7036-11, Rev. A): Find No. Part Number 1 2 3 4 5 6 193-8034-3 193-8039 3209T-1E 7004A-1 7005A-3 068-32-4/0 7 068-32-12/0 8 193-8044 11 12 13 090-301 074-761-1 074-921 14 15 18 MS24693-C3 NAS1635-04LR4 193-8135 19 20 089-4051 IM493 Description Quantity Used Reference Designator ASSY, BASE UNIT W /ETHERNET (+15V) MOUNTING PLATE ATTEN PRGM, W /SMARTSTEP PLANAR BULKHEAD, 2.
Model 8310-XX-X-XN IM-493 Model 8310-36-3-T-EN Attenuator Unit Assembly Replaceable Parts List (P/N 193-7038-13, Rev. A): Find No. Part Number 1 2 3 4 5 6 193-8034-3 193-8039 3209T-1E 7004A-1 7005A-3 068-32-4/0 8 11 12 13 193-8044 090-301 074-761-1 074-921 14 15 18 MS24693-C3 NAS1635-04LR4 193-8135 19 20 089-4051 IM493 Description ASSY, BASE UNIT W/ETHERNET (+15V) MOUNTING PLATE ATTEN PRGM W/SMARTSTEP PLANAR BULKHEAD, 2.
Model 8310-XX-X-XN IM-493 Model 8310-38-FN / -RN Attenuator Unit Assembly Replaceable Parts List (P/N 193-7038-9, Rev. A): Find No. Part Number 1 2 3 4 5 6 193-8034-3 193-8039 3206T-1 7004A-1 7005A-3 068-32-4/0 7 068-32-12/0 8 193-8041 11 12 090-301 074-761-1 13 074-921 14 15 18 MS24693-C3 NAS1635-04LR4 193-8135 19 20 089-4051 IM493 Description ASSY, BASE UNIT, W /ETHERNET (+15V) MOUNTING PLATE ATTEN PRGM, SMARTSTEP PLANAR BULKHEAD, 2.
Model 8310-XX-X-XN IM-493 Model 8310-38-3-TN Attenuator Unit Assembly Replaceable Parts List (P/N 193-7038-11, Rev. A): Find No. Part Number 1 2 3 4 5 6 193‐8034‐3 193‐8039 3206T‐1 7004A‐1 7005A‐3 068‐32‐4/0 8 193‐8041 11 12 13 090‐301 074‐761‐1 074‐921 14 15 18 MS24693‐C3 NAS1635‐04LR4 193‐8135 19 20 089‐4051 IM493 Description ASSY, BASE UNIT, W/ETHERNET (+15V) MOUNTING PLATE ATTEN PRGM, SMARTSTEP PLANAR BULKHEAD 2.
Model 8310-XX-X-XN IM-493 Model 8310-38-F / R-EN, Attenuator Unit Assembly Replaceable Parts List (P/N 193-7038-13, Rev. A): Find No. Part Number 1 2 3 4 5 6 193-8034-3 193-8039 3206T-1E 7004A-1 7005A-3 068-32-4/0 7 068-32-12/0 8 193-8041 11 12 13 090-301 074-761-1 074-921 14 15 18 MS24693-C3 NAS1635-04LR4 193-8135 19 20 089-4051 IM493 Description ASSY, BASE UNIT, W /ETHERNET (+15V) MOUNTING PLATE ATTEN PRGM W /SMARTSTEP INTERFACE PLANAR BULKHEAD 2.
Model 8310-XX-X-XN IM-493 Model 8310-38-3-EN, Attenuator Unit Assembly Replaceable Parts List (P/N 193-7038-15, Rev. A): Find No. Part Number 1 2 3 4 5 6 193-8034-3 193-8039 3206T-1E 7004A-1 7005A-3 068-32-4/0 8 193-8041 11 12 13 090-301 074-761-1 074-921 14 15 18 MS24693-C3 NAS1635-04LR4 193-8135 19 20 089-4051 IM493 Description ASSY, BASE UNIT, W /ETHERNET (+15V) MOUNTING PLATE ATTEN PRGM W /SMARTSTEP INTERFACE PLANAR BULKHEAD, 2.
Model 8310-XX-X-XN IM-493 Model 8310-138-FN / -RN, Attenuator Unit Assembly Replaceable Parts List (P/N 193-7138-5, Rev. A): Find No.
Model 8310-XX-X-XN IM-493 Model 8310-138-X-FN / -RN, Attenuator Unit Assembly Replaceable Parts List (P/N 193-7138-6, Rev. A): Find No. Part Number 1 2 3 193-8034-4 193-8084 101-2074-1 4 5 6 7004A-1 7005A-3 068-32-4/0 7 068-32-12/0 8 11 12 13 193-10806 090-301 074-761-1 074-921 14 15 18 NAS662C2LPR3 NAS1635-04LR4 193-8136 19 089-4066 20 IM493 Description ASSY, BASE UNIT, W/ETHERNET (+5V) MOUNTING PLATE ASSY, ATTEN, PRGM, 8 CELL, 103 dB/1 dB, SMA F/F PLANAR BULKHEAD, 2.
Model 8310-XX-X-XN IM-493 Model 8310-138-3-TN, Attenuator Unit Assembly Replaceable Parts List (P/N 193-7138-7, Rev. A): Find No. Part Number 1 2 3 193-8034-4 193-8084 101-2074-1 4 5 6 7004A-1 7005A-3 068-32-4/0 8 11 12 13 193-10806 090-301 074-761-1 074-921 14 15 18 NAS662C2LPR3 NAS1635-04LR4 193-8136 19 089-4066 20 IM493 Description ASSY, BASE UNIT, W/ETHERNET (+5V) MOUNTING PLATE ASSY, ATTEN, PRGM, 8 CELL, 103 dB/1 dB, SMA F/F PLANAR BULKHEAD, 2.
Model 8310-XX-X-XN IM-493 Model 8310-352-4-TN, Attenuator Unit Assembly Replaceable Parts List (P/N 193-7403-8, Rev. A): Find No. Part Number 1 2 3 193-8034-4 193-8084 101-2074-1 4 5 6 7004A-1 7005A-3 068-32-4/0 8 11 13 193-10806 090-301 074-921 14 15 18 NAS662C2LPR3 NAS1635-04LR4 193-8136 19 089-4066 20 IM493 Description ASSY, BASE UNIT, W/ETHERNET (+5V) MOUNTING PLATE ASSY, ATTEN, PRGM, 8 CELL, 103 dB/1 dB, SMA F/F PLANAR BULKHEAD, 2.
Model 8310-XX-X-XN IM-493 Model 8310-352-FN / -RN, Attenuator Unit Assembly Replaceable Parts List (P/N 193-7403-5, Rev. A): Find No. Part Number 1 2 3 4 5 6 193-8034-3 193-10265 3408T-103 7004A-1 7005A-3 068-32-4/0 7 068-32-12/0 8 11 12 13 193-8127 090-301 074-761-1 074-921 14 15 18 MS24693-C3 NAS1635-04LR4 193-8135 19 089-4065 20 IM493 Description ASSY, BASE UNIT W/ETHERNET (+15V) MOUNTING PLATE ATTEN PRGM, SMARTSTEP PLANAR BULKHEAD, 2.
Model 8310-XX-X-XN IM-493 Model 8310-352-2-FN / -RN, Attenuator Unit Assembly Replaceable Parts List (P/N 193-7403-6, Rev. A): Find No. Part Number 1 2 3 4 5 6 193-8034-3 193-10265 3408T-103 7004A-1 7005A-3 068-32-4/0 7 068-32-12/0 8 11 12 13 193-8127 090-301 074-761-1 074-921 14 15 18 MS24693-C3 NAS1635-04LR4 193-8135 19 089-4065 20 IM493 Description ASSY, BASE UNIT W/ETHERNET (+15V) MOUNTING PLATE ATTEN PRGM, SMARTSTEP PLANAR BULKHEAD, 2.
Model 8310-XX-X-XN IM-493 Model 8310-352-3-TN, Attenuator Unit Assembly Replaceable Parts List (P/N 193-7403-7, Rev. A): Find No. Part Number 1 2 3 4 5 6 193-8034-3 193-10265 3408T-103 7004A-1 7005A-3 068-32-4/0 8 11 12 13 193-8127 090-301 074-761-1 074-921 14 15 18 MS24693-C3 NAS1635-04LR4 193-8135 19 089-4065 20 IM493 Description Quantity Used Reference Designator ASSY, BASE UNIT W/ETHERNET (+15V) MOUNTING PLATE ATTEN PRGM SMARTSTEP PLANAR BULKHEAD 2.
Model 8310-XX-X-XN IM-493 Model 8310-352-4-TN, Attenuator Unit Assembly Replaceable Parts List (P/N 193-7403-8, Rev. A): Find No. Part Number 1 2 3 4 5 6 193-8034-3 193-10265 3408T-103 7004A-1 7005A-3 068-32-4/0 8 11 13 193-8127 090-301 074-921 14 15 18 MS24693-C3 NAS1635-04LR4 193-8135 19 089-4065 20 IM493 Description Quantity Used Reference Designator ASSY, BASE UNIT W/ETHERNET (+15V) MOUNTING PLATE ATTEN PRGM SMARTSTEP PLANAR BULKHEAD 2.
Model 8310-XX-X-XN IM-493 Assembly, Base Unit w/Ethernet (+15V) Replaceable Parts List (P/N 193-8034-3, Rev. A): Find No.
Model 8310-XX-X-XN IM-493 Assembly, Base Unit w/Ethernet (+5V) Replaceable Parts List (P/N 193-8034-4, Rev. A): Find No.
Model 8310-XX-X-XN IM-493 8. CONTACTING AEROFLEX / WEINSCHEL: In the event of a malfunction, contact Aeroflex / Weinschel. An apparent malfunction of an instrument or component may be diagnosed over the phone by first contacting the Customer Service Department at Aeroflex / Weinschel. DO NOT send the instrument or component back to the factory without prior authorization.
APPENDIX A APPENDIX A CARE AND HANDLING OF MICROWAVE COAXIAL CABLE ASSEMBLIES A-1 CARE AND HANDLING OF ASSEMBLIES. A-3 MAKING INITIAL CONNECTIONS. To ensure accurate measurements and optimal performance of Weinschel products, the microwave coaxial cable assemblies used in system and test setups must be properly used and maintained.
CARE & HANDLING OF COAXIAL CABLES A-4.2 HEX-NUT TYPES. To mate a connector of the hex-nut type, always use a torque wrench set to the correct torque value. Tighten the connector slowly until the wrench snaps. Tightening too quickly can cause the wrench to exceed its set limit. Do not snap the wrench more than once as this also causes overtorque. A-4.3 KNURLED NUTS. T ighten connectors with knurled nuts by hand. If this does not provide sufficient tightness use a hex-nut connector and torque wrench instead.
Model 8310-XX-X-XN IM-493 Model 8310 w/Ethernet (IM-493) Revision Record REVISION DATE DESCRIPTION APPLICABLE SERIAL NUMBERS A 8/08 Initial Issue All Units B 9/08 Added Models 8310-352-1-XN, 8310-352-3-TN, 8310-352-4-TN & 8310-138-X-XN Series All new Units C 8/09 Added Model 8310-1-XN, 8310-38-XN & 8310-2-XN Series All New Units D 12/09 Added Model 8310-36-XN Series All New Units E 1/09 Added Model 8310-35-XN Series All New Models Incorporated Aeroflex / Weinschel ECN 11-079.
EC DECLARATION OF CONFORMITY This is to certify that the: SmartStep Attenuator Unit 8310 Series Manufactured by: Weinschel Corporation Conforms with the protection requirements of Council Directive 89/336/EEC and the Amending Directive 93/68/EEC, relating to Electromagnetic Compatibility and Council Directive 73/23/EEC relating to LVD (Safety), by the application of: EN50081-1: 1992 Generic Emissions Standard. (Class B Equipment) EN50082-1: 1992 Generic Immunity Standard.