User's Guide

Form #: OP_01_TM
Title: Aeronix Data Links – EDL Nano Products User Guide
Document Number: AE301628-001
Revision: B Date: 3 October 2019
Aeronix Proprietary
49
3.6.4.2. MODIFY ENTRY Downstream Burst Profile Example
The user can modify a burst profile entry by selecting the MODIFY ENTRY button within the
Downstream Burst Profile section of the Profile Config page. The user can modify the CINR
entry and exit thresholds as well as the FEC entry and exit thresholds. The user can change the
available status of the profile by using the pull down menu in the Available field. Modifications
are saved and distributed through the network by selecting the SAVE button to the right of the
burst profile. If the user modifies the CINR entry and exit thresholds or the FEC entry and exit
thresholds to values outside of the recommend range, the values appear as red on the screen to
provide a warning even though they are used in the network.
Figure 3-39 BS 802.16 Example Modify Burst Profile