User's Guide

Form #: OP_01_TM
Title: Aeronix Data Links – EDL Nano Products User Guide
Document Number: AE301628-001
Revision: B Date: 3 October 2019
Aeronix Proprietary
80
Table 3-22. Subscriber Station Video Page
Field/Control
Description
packet and sent. The timer will be
started when the first byte is received.
Raw Buffer > 0, and Raw Timeout = 0
– The serial will buffer bytes until the
number of bytes on the serial match
the Raw Buffer bytes and then the
data will be packaged into a UDP
packet and sent.
Raw Buffer = 0 and Raw Timeout > 0
– The serial will buffer the amount of
bytes in the amount of time specified
by the Raw Timeout. The timer is
started at each interval, ie not when
the first byte is received.
Raw Buffer = 0, and Raw Timeout = 0
– This will package up a byte as it is
received from the serial.
Disable/Enable Flow Radio Buttons
Allows user to disable or enable the serial
flow control
Submit Button – Once submitted all of the
above changes will take effect
3.6.15. BS and SS Common Pages
3.6.15.1. Save Settings Button
The Save Settings button works the same for both the base station and subscriber. The Save
Settings button saves any changes that have been made on the GUI to the database with the
exception of the items mentioned in default database section that do not go back to default. All
modifications made and set take effect automatically at the time they are set with the exception
of generating start scripts. But, the changes do not get saved to the database unless the Save
Settings button is selected and confirmed. Changes made and not saved to the database will be
lost on a reboot or a power cycle. The save settings occurs for all screens simultaneously and not
just for the screen currently being browsed. A confirmation popup appears when the Save
Settings button gets selected.