User's Manual Part 1

User and Deployment Guide
25
(#3) CHAINING IN: Not supported.
CHAINING OUT: RJ-45 connector. This connector is used for distributing power
and data to chained Exciters or to connect an External LF Antenna. The output
voltage is 12 VDC (0.5 A maximum).
Termination Switch: Defining the termination settings in a chained Exciters
installation:
In regular chaining, the termination of the first and last Exciter in the chain
must be set to On (o-o) and the other Exciters set to Off (-o-o-).
The EX5700 Controller supports only being the first in a chain. The EX5700
cannot serve as a slave, e.g., the EX5700 cannot be chained to another EX5700.
Hence, the termination must be set to On (o-o).
Power Supply
The EX5700 Controller supports 24 V – 48 V power supply.
Product SKU
Power Supply 24 V US WGB-ADP-047-U
Power Supply 48 V US WGB-ADP-047-U
Power Supply 48 V Europe WGB-ADP-047-E
Power Supply 48 V UK WGB-ADP-047-UK
Altronix AL600ULM (UL294 central power supply) 80602001
Altronix AL175UL (UL294 central power supply) 15560
Altronix AL1024ULACMCB (UL294 central power
supply)
AGECP02-024
Note
It is prohibited to connect cables greater than 98.5 ft (30 m) long.