Connector Purpose Comment
R1 COM
Relay 1 common connection,
always connect
Dedicated to Maglock
control. With internal
feedback control.
R1 NO
Relay 1 normally open
connection
Dedicated to Maglock
control. With internal
feedback control.
R2 NC
Relay 2 normally closed
connection
R2 COM
Relay 2 common connection,
always connect
Dedicated to siren control.
With internal feedback
control.
R2 NO
Relay 2 normally open
connection
Dedicated to siren control.
With internal feedback
control.
GND
Ground/Earth
GND
Ground/Earth
D1
Wiegand Data 1 For Wiegand
communication with the
Outdoor Keypad
LED
Indication of Wiegand interface For Outdoor Keypad
12 V OUT
Power Used for powering Indoor
and Outdoor Keypads
D0
Wiegand Data 0 For Wiegand
communication with the
Outdoor Keypad
GND
Ground/Earth
DOOR IN
Door status Status on the door
(open/closed)
REX IN
Request for exit Controller moves to Bypass
mode