User's Manual Part 1

User and Deployment Guide
31
VISITOR MODE
x When the Visitor code is entered in the Keypad, relay 1 is set to
deactivated state.
x When the Visitor code is entered in the Keypad, relay 2 is set to
deactivated state.
x Visitor mode uses the Bypass time out period.
x During the Bypass timeout period, multiple people without Tags
are allowed to walk through the door
x If there is TIF during Visitor mode and door is open, relay 2 is
activated.
x Visitor is terminated if the door is not opened 5 seconds after the
visitor code is entered.
x Within the Bypass time out period, Visitor mode is terminated after
the door is closed.
x After Bypass timeout:
x In Night Mode, if the door is opened, the Controller switches to
Alarm Mode
x In Day Mode, if the door is opened and there is TIF, the Controller
switches to Alarm Mode
x Visitor code does not reset the alarm.
x If ‘alarm in’ or TIF, the Controller switches to Visitor Mode when the
Visitor code is entered and relay 1 gets deactivated.