User's Manual Part 1

User and Deployment Guide
35
Slave Exciter
A Slave Exciter can be connected to the EX5700 Controller. The Slave Exciter
allows extension of the LF range in the case of double doors or proximate door
that is controlled by the same EX5700 Controller as follows:
Exciter EX3210
x LF Exciter with 3 meters range
x Connected to the Controller via Cat5 cable
x Up to 3 Exciters can be chained with a single Controller power supply
EX5200 Exciter
x LF Exciter with 6.5 meters range
x Connected to the Controller via Cat5 cable
x Up to 2 Exciters can be chained with a single Controller power supply