User's Manual Part 1

User and Deployment Guide
39
Configuration of the Slave Exciter:
1.
The EX5700 is defined as the “Master.” Other Exciters are designated
“Slave.”
2. The Master Controller is connected to the first Slave Exciter as follows:
Master Chain OUT to Slave Chain IN.
3. Slave Exciters are then connected as follows: Slave OUT to Slave IN.
4. The Termination Switch of the Master and the last Slave Exciter in the chain
must be set to On (o-o).
On the other Slave Exciters, it must be set to OFF (-o o-).
For more information on Slave Exciter configuration and mounting, see the
EX3210 and EX5200 deployment guides here.
Mounting the EX5700 Controller
For standard mounting with standard mounting and heavy-duty mounting kits,
see Appendix A
.
For mounting using the Controller Wall-mount Bracket, see Appendix B.