User's Manual

Stanley Healthcare Confidential and proprietary
Preliminary information Subject to change. Ver. 1.0_DM
Connectors and Electrical Interfaces
16 pin connector
A 16-pin serial connector is used as an additional option to
externally power the tag. In addition it provides serial
interface for telemetry and configuration of the module
Pin
Description
Pin
Description
1
Pushbutton_2
9
Pushbutton_1
2
UART1_TX
10
UART1_RX
3
VCC_3.3V
11
UART2_RX
4
UART2_TX
12
NC
5
GND
13
NC
6
RESET
14
NC
7
WAKEUP
15
NC
8
ENABLE
16
NC
Mechanical Drawings
Installation Instruction
The TAG1200 module should be installed inside
equipment enclosure by keeping its location as
far as possible from metal parts to prevent RF
performance degradation
Before plugging the module into device, turn off
the device power and verify there is no live
power on the connector pins.
Connect the TAG1200 module to the device by
using board to board or wire to board
connector. Verify straight insertion and make
sure there are no bent or unconnected pins.
Use up to three screws (provided with the TAG1200
Module) to mount the module to the host device mechanics.
Turn the host power on. The device is ready for use.
OEM Instructions
a. The module is limited to OEM installation ONLY.
b. The OEM integrator is responsible for ensuring that the
end-user has no manual instructions to remove or install
the module.
c. The module is limited to installation in mobile or fixed
applications, according to Part 2.1091(b);
d. Separate approval is required for all other operating
configurations, including portable configurations with
respect to Part 2.1093 and different antenna
configurations;
e. Labeling instructions of finished products must contain
the following - “Contains Transmitter Module FCC ID:
Q3HTAG1200, IC: 5115A-TAG1200”
The OEM/Integrator must include the following
instructions/statements in the host user’s manual (i.e.
end product):
a. Statements required per FCC Part 15.19 and 15.21;
b. End-users must be provided with
transmitter/antenna installation requirements and
operating conditions for satisfying RF exposure
compliance:
i. A separate section should clearly state “FCC RF
Exposure requirements: “
ii. Required operating conditions for end users
iii. Antenna/or transmitter installation
requirements, where relevant
(For example: whether the antenna used with this module
must be installed to provide a separation distance of at least
30 cm from all persons, and must not transmit
simultaneously with any other antenna or transmitter.)
Please refer to KDB821551 for grant conditions for various
types of product.