To replace a battery:
1. Deactivate the tag with Tag Activator and Tag Manager (recommended).
2. Remove the rear panel by unscrewing the case screws.
3. Disconnect the battery connector from the board
4. Carefully remove the old battery from the battery holder.
Note
Do
not use a metal object to remove the battery
5. Connect the battery connector to the board.
6. Install a new 3.6V lithium Thionyl Chloride ½ 'AA' size battery in the battery
holder.
WARNING: Use only batteries that have been approved by AeroScout.
There is a danger of fatal tag damage if the battery is replaced incorrectly
or by an incorrect type. Dispose used batteries according to the
instructions.
7. Close the rear panel.
8. Activate the tag.
9. Dispose of the old Lithium Thionyl Chloride battery properly.
WARN
ING: Local regulations vary. Federal regulations allow up to 100
kg./month of Lithium Thionyl chloride batteries to be disposed in common
landfill. All leads (the terminals) should be taped to prevent short circuit.