Operation Manual Part 2

Aerosoft Digital Aviation
CRJ-70 & CRJ-900
AOM PART 2
Systems Description
VOL
5
5-1-30
26-Jul-2017
EICAS SYNOPTIC PAGE ELECTRICAL POWER SUPPLIED FROM AIR DRIVEN GENERATOR
EICAS DIGITAL READOUT
GREEN
WHITE
AMBER DASHES
XXX V
Between 108 and 130
volts
Less than 108 or more
than 130 volts
Invalid data
XXX HZ
Between 360 and 440 Hz
Less than 360 or more
than 440 Hz
Invalid data
EICAS OUTLINE
GREEN
WHITE
ADG outline green
ADG outline white
Voltage and frequency digital
readouts green
Voltage or frequency digital
readouts white