Operation Manual Part 2

Aerosoft Digital Aviation
CRJ-70 & CRJ-900
AOM PART 2
Systems Description
VOL
5
5-1-37
26-Jul-2017
1. SELECTED TEMPERATURE (cyan): Indicates the selected
temperature
2. ACTUAL TEMPERATURE (white): Indicates sensed
temperature
3. MANUAL (white): Indicates manual mode is selected.
4. SUPPLY DUCT TEMPERATURE (white): Displays sensed
temperature in the supply duct
ECAM MESSAGES
HI TEMP (amber): High temperature detected
AUTOFAIL (amber): Failure or pack in automatic mode is detected
L/R PACK AUTOFAIL CAUTION (amber): Pack failed in automatic mode and is NOT switched to manual
mode
L/R PACK TEMP CAUTION (amber): Temperature is > 85 °C
L/R PACK CAUTION (amber): Pack failed independent of mode (manual / automatic)
L/R PACK FAULT STATUS (white): Indicates a fault in the pack
L/R PACK OFF STATUS (white): Indicates pack is switched off
CKPT /CABIN TEMP MAN STATUS (white): Indicates that manual mode is selected
RAM AIR STATUS (white): Indicates ram air valve is open.
AFT CARGO OVHT CAUTION (amber): Temperatures over 40° sensed
AFT CARGO SOV STATUS (white): Air-inlet shut-off valve failed to open.
AVIONICS COOLING SYSTEM
All electrical systems heat up during use. Same goes for all the avionic in the cockpit. Given the restricted
space, cooling is necessary to prevent the avionic from overheating. Two display (DSPLY) fans supply cold air to
the displays only one of them is running during normal operation: on ground fan 2 and in flight fan 1.
Furthermore, two AVIONIC fans extract the heated air from behind the avionics. On ground fan 2 is powered
and in flight fan 1 is powered.
1. DISPLAY FANS CONTROLS
GND ALT: Select fan 1
during ground operations
NORM: Fans in exhaust
duct operate in automatic
mode to exhaust hot air from display and avionics compartments. Fan 1 used in flight, fan 2
used for ground operations