Operation Manual Part 2
Aerosoft – Digital Aviation
CRJ-70 & CRJ-900
AOM PART 2
Systems Description
VOL
5
5-1-8
26-Jul-2017
DISPLAY REVERSION
In case EICAS display ED1 fails, ED2 will automatically switch to primary page. In case EICAS display ED2 fails,
there is no automatic switch. With either display failed, the EICAS control panel is rendered inoperative. Please
switch the EICAS selector on the SOURCE SELECTOR PANEL to the operative display (ED1 or ED2). This re-
enables you to select and display the EICAS information on the selected display.
Furthermore, a revisionary panel is installed on either pilot’s side panel. They offer three positions:
• PFD 1, respective PFD 2
Switches the respective primary flight display (PFD1 = pilot, PFD 2 = co-pilot) to the adjacent MFD.
• NORM
PFD and MFD in normal operation
• EICAS
Shows the EICAS ED1 display on the MFD.