BRAKE TEMPERATURE MONITORING SYSTEM
The main wheel brakes temperature is monitored and indicated on the EICAS as long as the gear and flap/slats
position are indicated on the EICAS. In case an overheat condition is detected and no longer persists, the
warning may be reset by the BTMS overheat warning reset switch.
Each brakes temperature is indicated as a colour-coded numerical value:
Colour-code
Numerical values
Temperature range
Green
01 – 06
≤ 220°C
White
07 – 14
≥ 221°C and ≤ 492°C
Red
≥ 14
≥ 493°C