User's Manual

pulsAR radio Operator’s Manual
4-5
TDD ETHERNET
sync-mode: auto speed: auto
cycle: 20 ms station-timeout: 30 sec
split: auto multi-cast-timeout: 30 sec
Time-zone: GMT Single-node-timeout: 900 sec
Distance-max: 80 km
IP and SNMP:
IP Address: Netmask: Gateway:
No SNMP managers defined
Examples:
> display-configuration factory
> disco
load-configuration
source=main or alternate or basic or factory
Loads the specified configuration into the current set of parameters controlling the radio
operation. If no source is specified it defaults to the “main” configuration.
Examples:
> load-configuration source=factory
> load
lock
This command locks the access to all the commands that can alter the radio configuration.
Once locked use the “unlock” command to regain access to those commands. Note that a
password must be set prior to the “lock” command being issued (the radios are shipped with no
password), otherwise the lock command has no effect. If a password is set, the radio
automatically “locks” the configuration at the end of 10 minutes with no command activity.
save-configuration
destination=main or alternate
Saves the current set of radio operating parameters into one of the two non-volatile
configurations. If the destination is not specified it defaults to “main”.
Examples:
> save-configuration destination=alternate
> save