APPENDIX B – Specifications
RF Specifications AR-9010E AR-9027E AR-24010E AR-24027E AR-240110E
RF Frequency Band (MHz) 902 to 928 902 to 928 2400 to 2483 2400 to 2483 2400 to 2483
Signal Bandwidth (-20 dBc) 1.6 MHz 4.6 MHz 1.6 MHz 4.6 MHz 17 MHz
RF Channels (non-overlap): 10 3 35 11 3
Transmitter Output Power: 0 to 27 dBm 0 to 27 dBm 0 to 27 dBm 0 to 27 dBm 0 to 27 dBm
(dBm) (kbps) (dBm) (kbps) (dBm) (kbps) (dBm) (kbps) (dBm) (kbps)
Receiver Sensitivity
(10
-6
BER)
and Data Rates
-102 @
-99 @
-97 @
-94 @
100
200
550
1100
-100 @
-97 @
-95 @
-92 @
250
500
1375
2750
-97 @
-94 @
-92 @
-89 @
100
200
550
1100
-95 @
-92 @
-90 @
-87 @
250
500
1375
2750
-93 @
-90 @
-88 @
-85 @
1000
2000
5500
11000
Maximum Receive Signal -30 dBm (to stay in receiver linear region)
+20 dBm (to avoid damage)
Modulation Type direct sequence spread spectrum
Ethernet Port
Speed 10/100 BaseT, full/half duplex, auto-negotiate
Connector 8 pin circular (Lumberg 0321-08) - RJ45 at the power inserter
Networked Operation
Network topologies Point-to-point, point-to-multipoint, Mesh/Tree, Linear Network, Roaming
Management Telnet, SNMP (MIB2), or Econsole reach any node over wireless
Security Optional 3-DES or AES encryption, 32 bit network ID / password.
Console / Diagnostic Port
Interface RS-232/V.24, asynchronous 9600 to 115 kbaud
Connector 3 pin circular (Lumberg 0321-03) - cable adapter to DB9 available
Power
Input Voltage
Power over Ethernet compatible (+48VDC)
or +9.5 to +58 V DC or
110 to 220 VAC (with external supply)
Power Consumption less than 5 Watt
Transient Max. Peak Power 1500W (with 10/1000 us waveform)
Transient Max. Peak Current 35 A (with 10/1000 us waveform as defined by R.E.A.)
Environmental
Temperature -40 to +70 deg C (-40 to +158 deg F)
Max. Humidity Up to 95% non-condensing
Mechanical
Dimensions 4.72" wide x 8.66” high x 2.20” deep (120mm W x 220 H x 56 D)