Installation Guide

Wellington Aluminum Column
Wellington Aluminum Column
Wellington Aluminum Column
INSTALLATION INSTRUCTIONS
W
ELLINGTON
A
LUMINUM
C
OLUMN
AFCO INDUSTRIES, INC., P.O. BOX 5085, ALEXANDRIA, LA 71307
AFCO Form AL07-S Rev. 7/2013
For more information, contact Customer Service at 1-800-599-9912 or visit our website at www.afco-ind.com.
1. Measure the height of the opening where the column will be placed. Cut each col-
umn stave (piece)
1/4” longer than the opening. A circular saw with a metal cutting
blade is recommended for cutting the staves.
2. To assemble the column, snap the interlocks of two staves together beginning at
one end and continuing along the length of the column. Continue to add staves in
this manner, until all staves are together. Tap lightly with a rubber mallet if necessary
to ensure the joints are fully engaged.
4. To place and secure the column, set the column (with the capital base, and astragal
at the bottom) into place and plumb with a level. Raise the base and the capital and
attach the column to the floor with the appropriate fasteners and screws. Repeat at
the top of the column.
Note: High performance tie down brackets are available at an additional charge.
5. To secure the capital and astragal, gently, slide the capital to the top of the column.
Pre-drill holes and insert appropriate sized screws through the capital and the column
wall. Repeat with the astragal, positioning at the height desired (usually 12” - 18” be-
low capital. Allow the base to rest on the floor. It is not recommended to secure the
base to the floor or to the column.
Notes:
a. For best load-bearing performance, utilize AFCO load-bearing plates to spread the load over the entire perimeter of
the column. Load-bearing capacity is dependent on distributing the load evenly over the surfaces of the shaft.
b. All column staves should be cut square and to the same length.
c. Installation should be on a smooth level surface.
d. 2nd story balconies should not be attached directly to the side of any column.
e. Columns should be installed according to standard construction practices and in compliance with applicable local,
state, and federal regulations.
3. To install the capital, base, and astragal (if required) place the assembled column in
the upright base. Slide the astragal over the top of the column and all the way down
to rest on the base. Repeat with the capital. Do not secure.

Summary of content (2 pages)